首页 | 本学科首页   官方微博 | 高级检索  
检索        

ICP-MS技术测定清热解毒胶囊中常见金属元素的含量
引用本文:胡军高,梁旭霞,钟洪兰,李敏,王晶.ICP-MS技术测定清热解毒胶囊中常见金属元素的含量[J].中国药房,2012(35):3331-3333.
作者姓名:胡军高  梁旭霞  钟洪兰  李敏  王晶
作者单位:[1]广东省疾病预防控制中心,广州510300 [2]广州市胸科医院药剂科,广州510095
摘    要:目的:建立测定清热解毒胶囊中Fe、Cr、Mn、Ni、Cu、Zn、As、Ag、Cd、Sn、Sb、Ba、Pb13种常见金属元素含量的方法。方法:以湿法消解样品后,采用电感耦合等离子体质谱(ICP-MS)技术测定样品中金属元素的含量。结果:13种金属元素线性相关系数均>0.9990;方法准确度、精密度、稳定性均达到要求;有证参考物质榉木叶与茶叶验证方法准确度、精密度高。3批清热解毒胶囊中Cu、As、Cd、Pb的含量分别为0.7700、1.0200、0.0370、0.1400μg·g-1,0.8300、1.0500、0.0340、0.4100μg·g-1,0.8700、0.9300、0.0280、0.1200μg·g-1;Zn、Sn的含量分别为5.3000、0.0880μg·g-1,4.7100、0.1680μg·g-1,4.2400、0.2010μg·g-1。结论:本方法稳定、可靠。3批清热解毒胶囊中Cu、As、Cd、Pb的含量均符合国家中药材质量标准,Zn、Sn的含量符合国家相关食品标准,其余元素未见中药材标准限值。

关 键 词:清热解毒胶囊  电感耦合等离子体质谱技术  金属元素  标准限量

Content Determination of Common Metal Elements in Qingre Jiedu Capsule by ICP-MS
HU Jun-gao,LIANG Xu-xia,LI Min,WANG Jing.Content Determination of Common Metal Elements in Qingre Jiedu Capsule by ICP-MS[J].China Pharmacy,2012(35):3331-3333.
Authors:HU Jun-gao  LIANG Xu-xia  LI Min  WANG Jing
Institution:(Guangdong Center for Disease Control and Prevention, Guan- gzhou 510300, China) ZHONG Hong-lan (Dept. of Pharmacy, Guangzhou Chest Hospital, Guangzhou 510095, China)
Abstract:OBJECTIVE: To establish the method for the content determination of 13 common metal elements, Fe, Cr, Mn, Ni, Cu, Zn, As, Ag, Cd, Sn, Sb, Ba, Pb, in Qingre jiedu capsule. METHODS: The samples were wet digested by concentrated nitric acid (HNO3), and the contents of metal elements in wet digested samples were determined by ICP-MS. RESULTS: The lin- ear correlative coefficients for the common 13 elements were higher than 0.999 0. The accuracy, precision and stability of the meth- od were all in line with the standard; the validation method of certified reference substance the leaves of beech and tea was sound in accuracy and precision. The contents of Cu, As, Cd and Pb in 3 lots of Qingre jiedu capsules were 0.770 0, 1.020 0, 0.037 0, 0.140 0 μg.g^-1;0.830 0, 1.050 0,0.034 0,0.410 0 μg.g^-1;0.870 0,0.930 0,0.028 0,0.120 0 μg.g^-1, respectively. The contents of Zn and Sn were 5.300 0, 0.088 0μg.g^-1; 4.710 0,0.168 0 μg.g^-1;4.240 0,0.201 0 μg.g^-1. CONCLUSION: The method is steady and reliable. The contents of Cu, As, Cd and Pb in 3 lots of capsules meet national quality standards of TCM. The contents of Zn and Sn are up to national food quality standards. TCM standard limit of other elements haven' t been found.
Keywords:Qingre jiedu capsules  ICP-MS  Metal elements  Standard limit