摘    要:目的建立替硝唑胶囊含量测定中不确定度的分析方法。方法采用HPLC法测定含量的数学模型,确定影响不确定度的因素并对各个不确定度因素进行评估。结果替硝唑胶囊含量测定的合成不确定度为0.9%;扩展不确定度为1.8%;测定结果为(99.1±1.8)%。结论本方法可用于HPLC法测定该制剂含量的不确定度分析。

关 键 词:不确定度  HPLC法  含量测定  替硝唑胶囊

Uncertainty of the determination of Tinidazole Capsules
SUN Li. Uncertainty of the determination of Tinidazole Capsules[J]. Anhui Medical and Pharmaceutical Journal, 2010, 14(7): 776-777. DOI: 10.3969/j.issn.1009-6469.2010.07.015
Authors:SUN Li
Affiliation:SUN Li(Wuhu Institute for Food , Drug Control,Wuhu,Ahnhui 241001)
Abstract:Aim To establish a method for uncertainty analysis in HPLC determination.Method The calculation formula of uncertainty was deduced in the procedure of determining the content in capsules.Results The combined uncertainty was 0.9 %,the extended uncertainty was 1.8%,and the determined content were 99.1%±1.8%.Conclusion The mathematic model of uncertainty measurement established in this paper is reasonable and reliable.
Keywords:uncertainty  HPLC  content  tinidazole capsules  