首页 | 本学科首页   官方微博 | 高级检索  
     


Residual stress of porcelain-fused to zirconia 3-unit fixed dental prostheses measured by nanoindentation
Authors:Vinicius P. Fardin  Estevam A. Bonfante  Paulo G. Coelho  Malvin N. Janal  Nick Tovar  Lukasz Witek  Dimorvan Bordin  Gerson Bonfante
Affiliation:1. Department of Prosthodontics, University of Vila Velha, Vila Velha, ES, Brazil;2. Department of Prosthodontics and Periodontology, University of São Paulo — Bauru School of Dentistry, Bauru, SP, Brazil;3. Department of Biomaterials and Biomimetics, New York University, New York, NY, USA;4. Hansjörg Wyss Department of Plastic Surgery, NYU Langone Medical Center, New York, NY, USA;5. Department of Epidemiology and Health Promotion, New York University College of Dentistry, New York, NY, USA;6. Department of Operative Dentistry, Guarulhos University, Guarulhos, SP, Brazil
Abstract:

Objective

To evaluate the residual stress (nanoindentation based on hardness) of fatigued porcelain-fused to zirconia 3-unit fixed dental prostheses (FDP) with different framework designs.

Methods

Twenty maxillary 3-unit FDP replacing second-premolar (pontic) were fabricated with conventional framework-design (even-thickness of 0.5 mm and 9 mm2 connector area) and modified framework-design (thickness of 0.5 mm presenting lingual collar connected to proximal struts and 12 mm2 connector area). Connector marginal ridges were loaded and the fractured and suspended FDPs were divided (n = 3/each) into: (1) Fractured zirconia even-thickness (ZrEvenF); (2) Suspended zirconia even-thickness (ZrEvenS); (3) Fractured zirconia with modified framework (ZrModF); (4) Suspended zirconia with modified framework (ZrModS); (5) Non-fatigued FDP with conventional framework design (Control). The FDPs were nanoindented at 0.03 mm (Region of Interest (ROI) 1), 0.35 mm (ROI 2) and 1.05 mm (ROI 3) distances from porcelain veneer outer surface with peak load 4000 μN. The Linear Mixed Analysis of Variance (ANOVA) Model on ranks and Least Significant Difference Test on ranks (95%) were used.

Results

Highest rank hardness values were found for Control group and ZrModS, whereas the lowest values were found in ZrModF. Statistical differences (p = 0.000) were found among all groups except for comparison between ZrModS and Control group (p = 0.371). Hardness between ROIs were statistically significant different (p < 0.001) where ROI 1 presented the lowest values.

Significance

Framework-design modification did not influence the residual stress of porcelain-fused to zirconia fatigued 3-unit FDP. Whereas fractured FDPs showed the highest residual stress compared to suspended and control FDPs. Residual stress increased as nanoindented away from framework.
Keywords:Fatigue  Porcelain  Zirconia  Nanoindentation  Residual stress  Fixed dental Prostheses
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号