首页 | 本学科首页   官方微博 | 高级检索  
     


Reproducibility of different arrangement of resin copings by dental microstereolithography: Evaluating the marginal discrepancy of resin copings
Authors:Dong-Yeon Kim  Jin-Hun Jeon  Ji-Hwan Kim  Hae-Young Kim  Woong-Chul Kim
Affiliation:1. Doctoral student, Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University, Seoul, Republic of Korea;2. Assistant Professor, Department of Dental Technology, Medical Campus, KyungDong University, Gangwon-do, Republic of Korea;3. Professor, Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University, Seoul, Republic of Korea;4. Associate Professor, Department of Dental Laboratory Science and Engineering, College of Health Science, Department of Public Health Sciences, Graduate School, and BK21+ Program in Public Health Sciences, Korea University, Seoul, Republic of Korea;5. Professor, Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University, Seoul, Republic of Korea
Abstract:

Statement of problem

Microstereolithography (μ-SLA), a form of additive manufacturing, can produce one or more platforms of resin copings. However, no evaluation has been made of the variation in marginal discrepancy using this method, even though this is an important factor for a successful restoration.

Purpose

The purpose of this in vitro study was to evaluate the reproducibility and marginal discrepancy of resin copings fabricated using dental μ-SLA.

Material and methods

A master die of a mandibular right first molar tooth was made from Type IV stone and scanned to produce a stereolithography file. Resin copings were then fabricated using μ-SLA additive manufacturing by repeating 1, 3, or 6 arrays to give a total number of 18. The marginal discrepancies of these resin copings were measured using digital microscopy (at ×160 magnification), and the data obtained were analyzed using a nonparametric Kruskal-Wallis H test, post hoc Mann-Whitney U-test, and Bonferroni correction.

Results

The mean ±SD total marginal discrepancies of 1, 3, and 6 arrays were found to be 72.2 ±39.1 μm, 61.2 ±37.3 μm, and 92.5 ±54.1 μm. Statistically significant differences were found among the compared groups (P<.05).

Conclusions

Based on the marginal discrepancy, μ-SLA of additive manufacturing is more precise when 3 arrays are used than when 1 or 6 arrays are used on a single build platform. Because the fit is affected by the number of copings fabricated, further research of multiple resin copings is required.
Keywords:Corresponding author: Dr Woong-Chul Kim   College of Health Science   Korea University   145   Anam-ro   Seongbuk-gu   Seoul 136-713   REPUBLIC OF KOREA
本文献已被 ScienceDirect 等数据库收录!