The effect of mechanical cycling and different misfit levels on Vicker's microhardness of retention screws for single implant-supported prostheses
Authors:Wirley Gonçalves Assunção DDS  MSc   PhD  Juliana Ribeiro Pala Jorge DDS  MSc   PhD  Paulo Henrique Dos Santos DDS  MSc   PhD  Valentim Adelino Barão DDS  MSc  Érica Alves Gomes DDS  MSc   PhD  Juliana Aparecida Delben DDS  MSc
Affiliation:1. Associate Professor, Department of Dental Materials and Prosthodontics, Ara?atuba Dental School, Univ Estadual Paulista (UNESP), Sao Paulo, Brazil;2. Postgraduate Student, Department of Dental Materials and Prosthodontics, Ara?atuba Dental School, Univ Estadual Paulista (UNESP), Sao Paulo, Brazil;3. Assistant Professor, Department of Dental Materials and Prosthodontics, Ara?atuba Dental School, Univ Estadual Paulista (UNESP), Sao Paulo, Brazil
Abstract:Purpose: The aim of this study was to evaluate the effect of mechanical cycling and different misfit levels on Vicker's microhardness of retention screws for single implant‐supported prostheses. Materials and Methods: Premachined UCLA abutments were cast with cobalt‐chromium alloy to obtain 48 crowns divided into four groups (n = 12). The crowns presented no misfit in group A (control group) and unilateral misfits of 50 μm, 100 μm, and 200 μm in groups B, C, and D, respectively. The crowns were screwed to external hexagon implants with titanium retention screws (torque of 30 N/cm), and the sets were submitted to three different periods of mechanical cycling: 2×104, 5×104, and 1×106 cycles. Screw microhardness values were measured before and after each cycling period. Data were evaluated by two‐way ANOVA and Tukey's test (p < 0.05). Results: Mechanical cycling statistically reduced microhardness values of retention screws regardless of cycling periods and groups. In groups A, B, and C, initial microhardness values were statistically different from final microhardness values (p < 0.05). There was no statistically significant difference for initial screw microhardness values (p > 0.05) among the groups; however, when the groups were compared after mechanical cycling, a statistically significant difference was observed between groups B and D (p < 0.05). Conclusions: Mechanical cycling reduced the Vicker's microhardness values of the retention screws of all groups. The crowns with the highest misfit level presented the highest Vicker's microhardness values.
Keywords:Mechanical cycling  retention‐screw microhardness  implant‐supported prostheses  misfit
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号