首页 | 本学科首页   官方微博 | 高级检索  
     


Mathematical consideration of aqueous outflow after Trabeculo-Electropuncture (TEP)
Authors:Friedrich Hoffmann
Affiliation:(1) Eye Clinic, Klinikum Steglitz, Freie Universität Berlin, Hindenburgdamm 30, D-1000 Berlin 45
Abstract:Summary The obtainable postoperative intraocular pressure following a TEP in a glaucoma patient with an intraocular pressure of 30 mm Hg is calculated in accordance with the concept that there is no outflow of aqueous humor along Schlemm's canal. If aqueous humor reaches all collector channel openings in the surgical area without resistance, the postoperative intraocular pressure reads 14.75 mm Hg. This intraocular pressure is obtained at a point when a collector channel of 1 mm length and of 32 mgrm in diameter or two collector channels of 27 mgr in diameter or five collector channels of 22 mgr in diameter establish connection with the trabecular opening.
Zusammenfassung Der erreichbare postoperative Augendruck nach einer TEP bei einem Glaukompatienten mit dem Augendruck von 30 mm Hg wird unter der Vorstellung berechnet, daß es keinen Kammerwasserabfluß im Schlemmschen Kanal entlang gibt. Wenn das Kammerwasser alle Collector channel Öffnungen im Operationsgebiet ohne Widerstand erreicht, dann ist der postoperative Augendruck 14,75 mm Hg. Dieser intraokulare Druck wird dann erreicht, wenn ein Collector channel von 1 mm Länge und einem Durchmesser von 32 mgr oder zwei Collector channel mit einem Durchmesser von 27 mgr oder fünf Collector channel mit einem Durchmesser von 22 mgr mit der Trabekelöffnung in Verbindung stehen.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号