首页 | 本学科首页   官方微博 | 高级检索  
     


Measurement of uni-planar and sport specific trunk motion using magneto-inertial measurement units: The concurrent validity of Noraxon and Xsens systems relative to a retro-reflective system
Affiliation:1. School of Human Sciences (Exercise and Sport Science), University of Western Australia, Perth, Western Australia, Australia;2. Australian Institute of Sport, Canberra, Australian Capital Territory, Australia;3. School of Physiotherapy and Exercise Science, Curtin University, Perth, Western Australia, Australia;4. Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, Odense, Denmark;5. Minderoo Tech & Policy Lab (UWA Law School), University of Western Australia, Perth, Western Australia, Australia;6. Sports Performance Research Institute New Zealand (SPRINZ), Faculty of Health and Environmental Sciences, Auckland University of Technology, Auckland, New Zealand;1. Department of Kinesiology and Physical Education, Wilfrid Laurier University, Waterloo, ON, Canada;2. Univ Rennes, Inria, CNRS, IRISA, M2S, France;1. Université Côte d′Azur, LAMHESS, EUR HEALTHY, 06205, Nice, France;2. Université Côte d′Azur, CHU de Nice, Cimiez, Plateforme fragilité, 06000, Nice, France;3. Ted Orthopedics, 37 rue Guibal, 13003, Marseille, France;4. Institut Universitaire de France, 75231, Paris, France;1. Cambridge Centre for Sport and Exercise Sciences, Anglia Ruskin University, East Road, Cambridge, UK;2. School of Applied Sciences, Edinburgh Napier University, Sighthill Campus, Sighthill, Edinburgh, UK
Abstract:BackgroundThere is a range of magneto-inertial measurement unit (MIMU) systems commercially available, however sensor specifications and fusion methods vary considerably between manufacturers. Such variability can influence the concurrent validity of MIMUs relative to reference standard measurement devices. Different MIMUs have been compared during static or low-velocity conditions, with higher-velocity movements assessed in robotic-based studies. However, there is a need for the concurrent validity of higher-velocity movements to be established in human-based studies.Research questionThis study aimed to assess the concurrent validity of two commercial MIMU systems (Noraxon and Xsens), relative to a ‘gold-standard’ retro-reflective motion capture system, when measuring trunk angles during uni-planar range of motion (ROM) and cricket bowling, which involves high-speed, multi-planar movements.MethodsFor this criterion-based validity study, both MIMU systems incorporated comparable sensor specifications and employed Kalman filter sensor fusion algorithms. The MIMU based angles were compared with angles derived from concurrently captured three-dimensional retro-reflective data for 10 fast-medium bowlers. Statistical parametric mapping and root mean squared differences (RMSD) were computed for both MIMU systems.ResultsOne-dimensional statistical parametric mapping showed no significant differences for angles from both MIMU systems when compared with retro-reflective based angle outputs. The MIMU systems produced ROM RMSDs between 1.4 ± 1.0° and 2.6 ± 1.5°. One system displayed RMSDs between 4.6 ± 1.4° and 7.4 ± 1.9° during bowling, indicating functionally relevant differences to retro-reflective derived angles. There were some small but statistically significant differences in RMSDs between the MIMU systems.SignificanceMIMU-based angle accuracy is poorer during high-speed, multi-planar movement than uni-planar tasks. Comparable MIMU systems can produce varying measurements during ROM and bowling tasks. It is likely that varying sample rates and sensor fusion algorithm parameters contributed to the differences.
Keywords:Inertial measurement unit  Trunk  Bowling
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号