首页 | 本学科首页   官方微博 | 高级检索  
     

活动平台假体人工膝关节置换后的中期随访
引用本文:王国栋,;郭艾,;强华,;赵尔弘. 活动平台假体人工膝关节置换后的中期随访[J]. 中国临床康复, 2014, 0(26): 4101-4107
作者姓名:王国栋,  郭艾,  强华,  赵尔弘
作者单位:[1]首都医科大学附属北京同仁医院骨科,北京市100730; [2]首都医科大学附属北京友谊医院,北京市100050
基金项目:感谢北京友谊医院和北京同仁医院骨科全体医护人员给予的无私支持和帮助;感谢北京同仁医院放射科同事在影像学方面的支持.
摘    要:背景:虽然活动平台人工膝关节假体具有理论上的设计先进性以及体外运动学和磨损方面的优势,但临床效果是否优于固定平台假体目前尚不明确。目的:评估国人活动平台假体人工膝关节置换后的中期临床效果,为人工膝关节置换假体的选择提供临床依据。方法:纳入2006年12月至2009年6月于北京同仁医院采用旋转平台假体(PFC sigma RP)进行初次人工膝关节置换的膝关节骨关节炎和类风湿关节炎患者,对比观察患者置换前及置换后末次随访 KSS 评分、KSS功能评分、髌骨评分、膝前痛评、膝关节活动度、最大屈伸膝角度。记录患者置换后包括感染、髌骨弹响、聚乙烯垫片脱位、深静脉血栓等并发症情况。拍摄置换后标准的膝关节前后位、侧位及 Merchant 位 X 射线片,观察假体的力线、假体周围透亮区、髌骨脱位情况。将本组活动平台假体的随访结果与文献报道的固定平台假体人工膝关节置换的中期随访结果进行比较。结果与结论:最终共有31例45膝纳入试验,患者年龄(64.56±10.33)岁,随访时间3.9-7.6年。置换后末次随访时的各项评分、膝关节活动度及最大屈伸膝角度均较置换前明显改善,但与文献报道的固定平台置换后中期随访结果相当。未发现透亮线、假体松动、聚乙烯垫片脱出;虽然仅做了有限的髌外侧松解,所有患者均未出现髌骨脱位或半脱位;2例患者(2膝)出现髌骨弹响。提示活动平台膝关节置换后的中期临床效果满意。虽然仅做了有限的髌外侧松解,但没有发现髌骨脱位和半脱位,这可能是旋转平台设计上髌股关节方面优势的体现。

关 键 词:植入物  人工假体  关节植入物  活动平台  人工膝关节置换  中期随访

Medium-term follow-up after mobile-bearing total knee arthroplasty
Affiliation:Wang Guo-dong, Guo Ai, Qiang Hua, Zhao Er-hong (1Department of Orthopedics, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China; 2Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China)
Abstract:BACKGROUND:Mobile-bearing prosthesis has advantages in theoretic design, in vitro kinematics and abrasion, but it remains unclear whether its clinical outcomes are better than fixed-bearing prosthesis at present. OBJECTIVE:To evaluate the medium-term results of total knee arthroplasty using mobile-bearing prosthesis to provide clinical evidence for the choice of prosthesis. METHODS:The patients who suffered from osteoarthritis or rheumatoid arthritis and underwent total knee arthroplasty with PFC Sigma RP in Beijing Tongren Hospital from December 2006 to June 2009 were included in this study. The postoperative Knee Society Score, Knee Society Score Function Score, Patel ar Score and the Pain Score, range of motion, maximun flexion and extension angle were col ected and compared with pre-operation. The complications, such as infection, patel a clicking, polyethylene insert dislocation, and deep vein thrombosis were recorded after replacement. The anterior-posterior, lateral and Merchant position X-ray images were taken to evaluate the tibiofemoral alignment, radiolucent lines, and patel ar dislocation. Then, the results of other medium-term fol ow-up researches were compared with fixed-bearing arthroplasty. RESULTS AND CONCLUSION:Final y, 31 patients (45 knees) were fol owed up. The average age was 64.56±10.33 years, and fol ow-up period was 3.9-7.6 years. The postoperative scores, range of motion, maximun flexion and extension angle were improved obviously, but there were no differences with other medium-term fol ow-up researches. No radiolucent lines, prosthetic loosening or polyethylene insert dislocation was found. Lateral patel ar release was done, but no patel ar dislocation or subluxation appeared in al patients. Two patients (2 knees) accompanied patel a clicking. Results indicated that the medium-term clinical result was satisfactory. No patel ar dislocation or subluxation was found, although only lateral patel ar release was done. This may be the superiority of mobile-bearing
Keywords:arthroplasty,replacement,knee  osteoarthritis  prosthesis implantation  fol ow-up studies
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号