Wet-bulb globe temperature (WBGT)—its history and its limitations
Authors:Grahame M. Budd  
Affiliation:aSchool of Exercise and Sport Science, Faculty of Health Sciences, The University of Sydney, Australia
Abstract:Wet-bulb globe temperature (WBGT) is nowadays the most widely used index of heat stress, yet many users appear to be unaware of its history and its limitations.History of WBGT: WBGT was invented and first used during the 1950s as one element in a successful campaign to control serious outbreaks of heat illness in training camps of the United States Army and Marine Corps. Control measures based on air temperature and humidity, and applied to all trainees alike, had proved effective but had entailed excessive compliance costs in the form of lost training time. New control measures introduced in 1956 further reduced heat illness and also lost fewer training hours. Crucial innovations were (1) replacing the temperature and humidity measurements with WBGT, which additionally responds to sun and wind, (2) using epidemiologic analyses of casualty records to identify hazardous levels of WBGT and vulnerable trainees, and (3) protecting the most vulnerable trainees by suspending drill at lower levels of WBGT, and by improving their heat tolerance in special conditioning platoons. This campaign has considerable relevance to the prevention of heat illness in sport.Limitations of WBGT: WBGT's most serious limitation is that environments at a given level of the index are more stressful when the evaporation of sweat is restricted (by high humidity or low air movement) than when evaporation is free. As with all indices that integrate elements of the thermal environment, interpretation of the observed levels of WBGT requires careful evaluation of people's activity, clothing, and many other factors, all of which can introduce large errors into any predictions of adverse effects. Moreover, the accuracy of WBGT is being eroded by measurement errors associated with the omission of the globe temperature, with non-standard instrumentation, and with unsatisfactory calibration procedures. Because of the above limitations WBGT can provide only a general guide to the likelihood of adverse effects of heat. A much clearer assessment can be obtained by measuring the individual elements of the thermal environment, and using those measurements to estimate the requirement for evaporative cooling, the likelihood of achieving it, and more accurate and comprehensive indices of heat stress.
Keywords:Heat stress   Calibration of heat stress meters   Heat illness   Prevention
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号