首页 | 本学科首页   官方微博 | 高级检索  
     


The role of speckle tracking echocardiography in assessment of lipopolysaccharide-induced myocardial dysfunction in mice
Authors:Ming Chu  Yao Gao  Yanjuan Zhang  Bin Zhou  Bingruo Wu  Jing Yao  Di Xu
Affiliation:1.Department of Geriatrics, 2.Department of Cardiology, First Affiliated Hospital with Nanjing Medical University, Nanjing 210029, China; 3.Departments of Genetics, Pediatrics and Medicine (Cardiology), Albert Einstein College of Medicine of Yeshiva University, New York, NY, USA
Abstract:

Background

Sepsis-induced myocardial dysfunction is a common and severe complication of septic shock. Conventional echocardiography often fails to reveal myocardial depression in severe sepsis due to hemodynamic changes; in contrast, decline of strain measurements by speckle tracking echocardiography (STE) may indicate impaired cardiac function. This study investigates the role of STE in detecting lipopolysaccharide (LPS)-induced cardiac dysfunction with mouse models.

Methods

We evaluated cardiac function in 20 mice at baseline, 6 h (n=10) and 20 h (n=10) after LPS injection to monitor the development of heart failure induced by severe sepsis using 2-D and M-mode echocardiography. Ejection fraction (EF) and fractional shortening (FS) were measured with standard M-mode tracings, whereas circumferential and radial strain was derived from STE. Serum biochemical and cardiac histopathological examinations were performed to determine sepsis-induced myocardial injury.

Results

Left ventricular (LV) myocardial function was significantly reduced at 6 h after LPS treatment assessed by circumferential strain (−14.65%±3.00% to −8.48%±1.72%, P=0.006), whereas there were no significant differences between 6 and 20 h group. Conversely, EF and FS were significantly increased at 20 h when comparing to 6 h (P<0.05) accompanied with marked decreases in EF and FS 6 h following LPS administration. Consistent with strain echocardiographic results, we showed that LPS injection leaded to elevated serum level of cardiac Troponin-T (cTnT), CK-MB and rising leucocytes infiltration into myocardium within 20 h.

Conclusions

Altogether, these results demonstrate that, circumferential strain by STE is a specific and reliable value for evaluating LPS-induced cardiac dysfunction in mice.
Keywords:Sepsis   septic cardiomyopathy   endotoxin-induced cardiac dysfunction   strain imaging   speckle tracking echocardiography (STE)
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号