摘    要:本文着重讨论在高血糖时间CoulterJT-IR血细胞计数仪测定MCV引假性增高情况。用EDTA-K2抗凝,制备10个不同葡萄糖浓度的抗凝血,按0.5、2.5、5.0、8.0h四个时间用Coulter计数仪测MCV值,用日立7150自动生分析则区区糖浓度。

关 键 词:高血糖症 红细胞 血细胞计数仪 平均体积

Effect of hyperglycemia on MCV measurement
LIN Jun,LI Yong,GE Yifeng,MENG Ze. Effect of hyperglycemia on MCV measurement[J]. Chinese Journal of Clinical Laboratory Science, 1998, 16(5): 280-283
Authors:LIN Jun  LI Yong  GE Yifeng  MENG Ze
Abstract:The false increase of MCV in hyperglycemia was discussed in this article. Different amount of glucose was added into EDTA K 2 blood and the concentration of glucose was measured on HITACHI 7150 Automated Biochemical Analyzer. MCV was determined with Coulter JT IR electronic cell counter at 0 5,2 5,5 0,8 0 h after addition of glucose. The result showed the positive relevance between MCV and glucose concentration. MCV was significantly increased when glucose concentration was more than 90 mmol/L. False increase of MCV was also observed in higher blood BU with absence of hyperglycemia.
Keywords:hyperglycemia  mean cell volume(MCV)  electronic cell counter  false increase  