首页 | 本学科首页   官方微博 | 高级检索  
     


A microfluidic device for continuous manipulation of biological cells using dielectrophoresis
Affiliation:1. Department of Electrical Engineering, Indian Institute of Technology, Kharagpur 721302, India;2. School of Medical Science and Technology, Indian Institute of Technology, Kharagpur 721302, India;1. Department of Electrical Engineering and Center for Micro/Nano Science and Technology, National Cheng Kung University, Taiwan;2. Department of Electrical Engineering, Chinese Culture University, Taiwan;1. FlexMEMS Research Centre, Department of ECE, Manipal University Jaipur, Jaipur 303007, India;2. Nano Biosensors Group, Central Electronics Engineering Research Institute, Pilani 333031, India;3. Department of Mechanical Engineering, Manipal University Jaipur, Jaipur 303007, India;1. Department of Human Nutrition, Food and Animal Sciences, University of Hawaii at Manoa, Honolulu, HI 96822, USA;2. Department of Molecular Biosciences and Bioengineering, University of Hawaii at Manoa, Honolulu, HI 96822, USA;1. Metrology and Advanced Mechatronics Laboratory, Department of Mechanical Engineering, Tarbiat Modares University, Tehran, Iran;2. Hematology Laboratory, Department of Medical Sciences, Tarbiat Modares University, Tehran, Iran
Abstract:The present study demonstrates the design, simulation, fabrication and testing of a label-free continuous manipulation and separation micro-device of particles/biological cells suspended on medium based on conventional dielectrophoresis. The current dielectrophoretic device uses three planner electrodes to generate non-uniform electric field and induces both p-DEP and n-DEP force simultaneously depending on the dielectric properties of the particles and thus influencing at least two types of particles at a time. Numerical simulations were performed to predict the distribution of non-uniform electric field, DEP force and particle trajectories. The device is fabricated utilizing the advantage of bonding between PDMS and SU8 polymer. The p-DEP particles move away from the center of the streamline, while the n-DEP particles will follow the central streamline along the channel length. Dielectrophoretic effects were initially tested using polystyrene beads followed by manipulation of HeLa cells. In the experiment, it was observed that polystyrene beads in DI water always response as n-DEP up to 1 MHz frequency, whereas HeLa cells in PBS medium response as n-DEP up to 400 kHz frequency and then it experiences p-DEP up to 1 MHz. Further, the microscopic observations of DEP responses of HeLa cells were verified by performing trapping experiment at static condition.
Keywords:DEP  Continuous particles manipulation  Microfluidics  COMSOL
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号