首页 | 本学科首页   官方微博 | 高级检索  
检索        


Modified cannulated screw fixation in the treatment of Pauwels type III femoral neck fractures: A biomechanical study
Institution:1. Department of Orthopedics, Shanghai Tenth People''s Hospital, Tongji University School of Medicine, Shanghai, 200072, China;2. Shanghai Trauma Emergency Center, Shanghai, 200072, China;3. Orthopedic Intelligent Minimally Invasive Diagnosis & Treatment Center, Shanghai Tenth People''s Hospital, Tongji University School of Medicine, Shanghai, 200072, China;1. The Second Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou 510006, China;2. The Second Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine, Guangzhou University of Chinese Medicine, Guangzhou 510006, China
Abstract:BackgroundAchieving satisfactory internal fixation for patients with Pauwels type III femoral neck fractures has become a critical problem. The purpose of this study was to compare a common standard internal reduction and fixation method for femoral neck fractures to the modified fixation methods.MethodsA computed tomography scan of the femur was performed to make a Three-dimensional (3D) model, and a fracture line was simulated in the femoral neck. 3Dfinite element analysis was carried out for different insertion methods of cannulated tension screws. Six healthy femur specimens were harvested from three formalin-fixed cadavers, and Pauwels type III femoral neck fracture was artificially created in bilateral femurs. The right side was treated with the inverted triangle construct method and the left side by the modified screw fixation method. After fixation, uniaxial compression and maximum load experiments on the bilateral femoral necks were carried out using the non-contact full-field dynamic strain measurement system (VIC-3D) on a pressure testing machine.FindingsBoth 3D finite element analysis and biomechanical study showed that the modified screw fixation method(group D) provided better anti-shearing and anti-rotation properties for Pauwels type III femoral neck fractures, and offered better interfragmentary compression. Therefore, this modified screw fixation method can offer patients a better option for treatment of Pauwels type III femoral neck fractures.InterpretationChanging the placement of the anterosuperior screw in the inverted triangle construct as perpendicular to the fracture line has the advantages in anti-shearing, anti-rotation and increasing interfragmentary compression.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号