首页 | 本学科首页   官方微博 | 高级检索  
     


Validation and Pharmacokinetic Application of a High-Performance Liquid Chromatographic Technique for Determining the Concentrations of Amodiaquine and Its Metabolite in Plasma of Patients Treated with Oral Fixed-Dose Amodiaquine-Artesunate Combination in Areas of Malaria Endemicity
Authors:Olumuyiwa N. Adedeji  Oluseye O. Bolaji  Catherine O. Falade  Odusoga A. Osonuga  Olusegun G. Ademowo
Affiliation:aDepartment of Pharmacology and Therapeutics, Faculty of Basic Medical Sciences, University of Ibadan, Ibadan, Nigeria;bDepartment of Pharmaceutical Chemistry, Faculty of Pharmacy, Obafemi Awolowo University, Ile-Ife, Nigeria;cInstitute for Advanced Medical Research and Training, College of Medicine, University of Ibadan, Ibadan, Nigeria;dOlabisi Onabanjo University, Department of Pharmacology, College of Health Sciences, Sagamu, Nigeria
Abstract:Artemisinin-based combination therapies (ACTs) have been adopted by most African countries, including Nigeria, as first-line treatments for uncomplicated falciparum malaria. Fixed-dose combinations of these ACTs, amodiaquine-artesunate (FDC AQAS) and artemether-lumefantrine (AL), were introduced in Nigeria to improve compliance and achieve positive outcomes of malaria treatment. In order to achieve clinical success with AQAS, we developed and validated a simple and sensitive high-performance liquid chromatography (HPLC) method with UV detection for determination of amodiaquine (AQ) and desethylamodiaquine (DAQ) in plasma using liquid-liquid extraction of the drugs with diethyl ether following protein precipitation with acetonitrile. Chromatographic separation was achieved using an Agilent Zorbax C18 column and a mobile phase consisting of distilled water-methanol (80:20 [vol/vol]) with 2% (vol/vol) triethylamine, pH 2.2, at a flow rate of 1 ml/min. Calibration curves in spiked plasma were linear from 100 to 1,000 ng/ml (r > 0.99) for both AQ and DAQ. The limit of detection was 1 ng (sample size, 20 μl). The intra- and interday coefficients of variation at 150, 300, and 900 ng/ml ranged from 1.3 to 4.8%, and the biases were between 6.4 and 9.5%. The mean extraction recoveries of AQ and DAQ were 80.0% and 68.9%, respectively. The results for the pharmacokinetic parameters of DAQ following oral administration of FDC AQAS (612/200 mg) for 3 days in female and male patients with uncomplicated falciparum malaria showed that the maximum plasma concentrations (Cmax) (740 ± 197 versus 767 ± 185 ng/ml), areas under the plasma concentration-time curve (AUC) (185,080 ± 20,813 versus 184,940 ± 16,370 h · ng/ml), and elimination half-life values (T1/2) (212 ± 1.14 versus 214 ± 0.84 h) were similar (P > 0.05).
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号