Therapeutic Anticoagulation With an Ultra-Low Concentration Argatroban-Based Purge Solution for Percutaneous Ventricular Assist Device in Patient With Heparin-Induced Thrombocytopenia
Authors:Andrea Sikora Newsome  Ashley Taylor  Seth Garner
Affiliation:1.The University of Georgia College of Pharmacy, Augusta, USA
Abstract:Purpose/Background: Percutaneous left ventricular assist devices (pVADs) require a continuous purge solution containing heparin to prevent pump thrombosis and device failure. Data regarding alternative options in patients who have suspected heparin-induced thrombocytopenia (HIT) are limited. Methods: In this report, we describe a 68-year-old white man with cardiogenic shock with an Impella CP device managed with a low concentration argatroban-based purge solution secondary to a suspected diagnosis of HIT. Results: The purge solution was initiated as argatroban in dextrose 10% at a concentration of 0.12 mg/mL and was subsequently decreased twice to 0.06 and 0.015 mg/mL based on the patient’s clinical course. Conclusions: This case report describes the safe and effective use of argatroban purge solution necessary for anticoagulation although further studies are needed to confirm these findings.
Keywords:gram-negative bacteria   pseudomonas aeruginosa   microbiology   anti-bacterial agents   intensive care units