首页 | 本学科首页   官方微博 | 高级检索  
     

离子对高效液相色谱法测定人血中二甲双胍含量
引用本文:林观样,张秀华,张春红. 离子对高效液相色谱法测定人血中二甲双胍含量[J]. 中国现代应用药学, 2005, 22(3): 241-243
作者姓名:林观样  张秀华  张春红
作者单位:温州医学院附属第一医院,浙江,温州,325000
摘    要:目的建立离子对-HPLC法测定人血中二甲双胍含量的方法.方法采用ODSC18色谱柱(4.6mm×250mm,5μm);以甲醇-磷酸二氢钾溶液(含0.03mol·mL-1庚烷磺酸钠,pH4.7)(4060)为流动相,流速1.0mL·min-1,紫外检测波长232nm,柱温37℃.结果离子对-HPLC法测定人血中二甲双胍的线性范围0.25~4μg·mL-1,相关系数0.9993.日内差异、日间差异均小于10%,绝对回收率大于80%.结论本法适用于二甲双胍血药浓度测定.

关 键 词:离子对-HPLC 二甲双胍 含量测定

Ion pair HPLC assay of metformin hydrochloride in human plasma
LIN Guan-yang,ZHANG Xiu-hu,ZHANG Chun-hong. Ion pair HPLC assay of metformin hydrochloride in human plasma[J]. The Chinese Journal of Modern Applied Pharmacy, 2005, 22(3): 241-243
Authors:LIN Guan-yang  ZHANG Xiu-hu  ZHANG Chun-hong
Abstract:OBJECTIVE A HPLC method was established for the assaying of metformin in human plasma. METHODS The mosulfonate and adjusted to pH 4.7 by phosphoric acid) (40:60) ,the flow rate was 1.0mL/min, the detection was carried out with a than 10%. CONCLUSION The method is simple, rapid, and accurate, and it is suitable for the determination of metformin in the human plasma.
Keywords:ion pair HPLC  metformin  assay
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《中国现代应用药学》浏览原始摘要信息
点击此处可从《中国现代应用药学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号