首页 | 本学科首页   官方微博 | 高级检索  
     


In vivo diffusion-weighted imaging of liver tumor necrosis in the VX2 rabbit model at 1.5 Tesla
Authors:Deng Jie  Rhee Thomas K  Sato Kent T  Salem Riad  Haines Kenneth  Paunesku Tatjana  Mulcahy Mary F  Miller Frank H  Omary Reed A  Larson Andrew C
Affiliation:Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Il 60611, USA.
Abstract:OBJECTIVES: We sought to demonstrate the feasibility of using single-shot spin-echo echo-planar imaging for imaging liver tumor necrosis in the in vivo VX2 rabbit model at 1.5 T. MATERIALS AND METHODS: VX2 liver tumors were grown in 4 rabbits. Diffusion-weighted images (DWIs) were acquired during breath-hold using twice refocused SE-EPI (b = 0, 700, 1400 seconds/mm). Anatomic images for tumor size measurements were acquired using T2W TSE. Rabbits were euthanized for subsequent necropsy. Viable and necrotic tumor tissue ADC measurements were performed with reference to hematoxylin and eosin pathology. RESULTS: A total of 8 tumors were grown with diameters ranging from 1.2 to 5.3 cm. Viable and necrotic tumor compartments were clearly differentiated. Apparent diffusion coefficient in necrotic tumor cores, 1.26 +/- 0.11 x 10 mm/s, were significantly greater than those in surrounding viable tumor tissues, 0.74 +/- 0.06 x 10 mm/s (mean +/- SD, P < 0.05). CONCLUSIONS: In vivo DWI of liver tumor necrosis in the VX2 rabbit model is feasible using a 1.5 T clinical magnetic resonance imaging scanner. DWI may permit longitudinal assessment of liver tumor therapies in both preclinical and clinical studies.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏