首页 | 本学科首页   官方微博 | 高级检索  
检索        


The influence of patellar resurfacing on patellar kinetics and retropatellar contact characteristics
Authors:Simone Wurm  Hans Kainz  Wolfgang Reng  Peter Augat
Institution:1. Institute of Biomechanics, Trauma Center Murnau, Prof.-Küntscher-Str. 8, 82418, Murnau, Germany
2. Department of Traumatology, Trauma Center Murnau, Prof.-Küntscher-Str. 8, 82418, Murnau, Germany
Abstract:

Background

Femoropatellar complications are one of the most common problems after total knee arthroplasty (TKA). However, the question of whether to resurface the patella remains controversial. Therefore, we evaluated the kinetics and the retropatellar contact characteristics of patella resurfacing with fixed and gliding surfaces.

Methods

Eight Thiel-embalmed cadaver knees were tested—first intact, then after TKA without patellar resurfacing, and finally with additional patellar resurfacing—while flexing the knee from 0° to 100°. We tested a fixed as well as a gliding patella surface. During the examination, quadriceps and hamstring forces were applied. The retropatellar pressure was determined with a special patella sensor, and the patellar kinetics were measured using an optical three-dimensional motion analysis system.

Results

Resurfacing the patella caused a significant increase in retropatellar pressure and a significant decrease in retropatellar contact area. Using a fixed patella, the retropatellar pressure nearly quadrupled in higher flexion compared to the native patella. Furthermore, the lateral movement of the patella increased after TKA, especially after additional patellar resurfacing.

Conclusions

Resurfacing the patella routinely is not advised. When osteoarthritis of the patella is found, the gliding patella should be preferred.
Keywords:
本文献已被 ScienceDirect SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号