首页 | 本学科首页   官方微博 | 高级检索  
     

自制交锁髓内钉固定锁骨中段骨折的解剖学研究
引用本文:罗轶,彭永岳,杨永富,任振华,李光武,孙玉强. 自制交锁髓内钉固定锁骨中段骨折的解剖学研究[J]. 中华创伤杂志, 2010, 26(2). DOI: 10.3760/cma.j.issn.1001-8050.2010.02.006
作者姓名:罗轶  彭永岳  杨永富  任振华  李光武  孙玉强
作者单位:1. 上海市第六人民医院金山分院骨科,201500
2. 安徽医科大学解剖教研室
3. 上海市第六人民医院骨科
基金项目:上海市卫生局资助项目 
摘    要:目的 根据锁骨的解剖学特点,研制一种交锁髓内钉固定锁骨中段骨折,并探讨其优缺点. 方法 通过对60根成人锁骨及5具成人新鲜尸体标本的测量、实验,测量锁骨长度、外侧段与中段夹角、中段与内侧段夹角、锁骨最窄处直径、锁骨最窄处髓腔内径等数据.设计出交锁髓内钉,其两端结构相同,均可与瞄准器相连接,采用逆行穿钉及两端锁定的方法固定锁骨中段骨折. 结果 锁骨全长为(14.82±1.15)cm,外侧段与中段夹角、中段与内侧段夹角均为30°左右,锁骨最窄处直径为(1.00±0.16)cm,锁骨最窄处髓腔内径为(0.50±0.18)cm.由锁骨中段骨折端逆行穿导针并扩髓,根据锁骨的形状适度折弯髓内钉,由近端或远端插入髓腔,分别用瞄准器锁定远、近端,固定稳定可靠. 结论 采用自制交锁髓内钉固定锁骨中段骨折手术创伤小,直视下复位满意而且固定可靠.但相关生物力学数据还有待于进一步研究.

关 键 词:锁骨  骨折固定术    解剖学

Anatomical study on self-made intramedullary nails for fixation of clavicular fractures
LUO Yi,PENG Yong-yue,YANG Yong-fu,REN Zhen-hua,LI Guang-wu,SUN Yu-qiang. Anatomical study on self-made intramedullary nails for fixation of clavicular fractures[J]. Chinese Journal of Traumatology, 2010, 26(2). DOI: 10.3760/cma.j.issn.1001-8050.2010.02.006
Authors:LUO Yi  PENG Yong-yue  YANG Yong-fu  REN Zhen-hua  LI Guang-wu  SUN Yu-qiang
Abstract:Objective To design an intramedullary nail that had the same ends and could be connected to hairline pointer and employ it to fixate mid-shaft clavicular fractures. Methods Sixty adult clavicles and five fresh adult cadaveric clavicles were employed to measure full length, angle between lateral and middle segments, angle between middle and medial segments as well as the narrowest outer and inner diameters of the clavicle. The interlocked intramedullary nail with the same structure of two ends was designed and used to fixate mid-shaft clavicular fractures. The nail was inserted in retrograde manner and locking screws could be inserted at beth ends. Results The full length, angle between lateral and middle segments, angle between middle and media] segments as well as the narrowest outer and inner diameters of the clavicle were (14.82 ± 1.15) cm, 30°, 30°, (1.00±0.16) cm and (0.50± 0. 18) cm respectively. After conversely placing guide pin from the fracture end, expanding medullary cavity and adjusting the nail, the designed nail was inserted into the medullary cavity from the distal or proximal ends of the clavicle, which was locked by interlocked screws. Conclusions Self-made nail takes advantages of less surgical invasion, visible fracture reduction and stable fracture fixation for treatment of mid-shaft clavicular fractures. While the biomechanieal properties of the nail need further investigation.
Keywords:Clavicle  Fracture fixation  internal  Anatomy.
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号