首页 | 本学科首页   官方微博 | 高级检索  
     

早产大鼠动脉导管开放模型的建立
引用本文:朱梦茹,刘海岩,刘盼盼,武辉. 早产大鼠动脉导管开放模型的建立[J]. 中国当代儿科杂志, 2016, 18(4): 372-375. DOI: 10.7499/j.issn.1008-8830.2016.04.018
作者姓名:朱梦茹  刘海岩  刘盼盼  武辉
作者单位:朱梦茹;1., 刘海岩;2., 刘盼盼;1., 武辉;1.
基金项目:吉林省科技厅自然科学基金(20160101071JC)。
摘    要:目的 利用改良的自然发育法构建早产大鼠动脉导管开放模型.方法 基于自然发育法在构建早产大鼠动脉导管开放模型上的缺陷,本研究对实验技术进行了改进,避免固定方式、脱水处理及切片方式对血管管径的影响.将1 只孕19 d 的Wistar 大鼠行剖宫产,取出8 只新生大鼠,脱臼处死后整体包埋、避免脱水、微距切片、水平切片,苏木精-伊红染色后镜下测量动脉导管、主肺动脉、降主动脉内径.结果 孕19 d 大鼠剖宫产术后8 只新生大鼠动脉导管均开放.各血管内径测量结果显示:降主动脉长径:354±106 μm,短径:182±140 μm;动脉导管短径:155±122 μm,面积:36 847±42 582 μm2;主肺动脉长轴:589±150 μm,短轴:174±170 μm.结论 改良的早产大鼠动脉导管开放模型成功构建.

关 键 词:动脉导管开放  动物模型  早产  大鼠  
收稿时间:2015-12-04
修稿时间:2016-03-01

Establishment of the patent ductus arteriosus model in preterm rats
ZHU Meng-Ru,LIU Hai-Yan,LIU Pan-Pan,WU Hui. Establishment of the patent ductus arteriosus model in preterm rats[J]. Chinese journal of contemporary pediatrics, 2016, 18(4): 372-375. DOI: 10.7499/j.issn.1008-8830.2016.04.018
Authors:ZHU Meng-Ru  LIU Hai-Yan  LIU Pan-Pan  WU Hui
Affiliation:ZHU Meng-Ru;1., LIU Hai-Yan;2., LIU Pan-Pan;1., WU Hui;1.
Abstract:ObjectiveTo establish the patent ductus arteriosus model in preterm rats using the improved natural development method.MethodsIn the light of the lfaws of the natural development method in establishing the patent ductus arteriosus model, the experimental technology was modified to avoid the influence of fixation, dehydration, and section method on blood vessel diameter. Cesarean section was performed for a Wistar rat pregnant for 19 days, and 8 neonatal rats were obtained. After they were sacriifced by dislocation, they were embedded as a whole to avoid dehydration, and the microsection and horizontal section were made. After hematoxylin and eosin staining, a microscope was used to measure the inner diameters of the ductus arteriosus, the main pulmonary artery, and the descending aorta.ResultsAfter the cesarean section for the rat pregnant for 19 days, patent ductus arteriosus occurred in all the 8 neonatal rats. The measurements of the inner diameters of blood vessels were as follows: the long diameter and short diameter of the descending aorta were 354±106 and 182±140 μm, respectively; the short diameter of the ductus arteriosus was 155±122 μm, and its area was 36 847±42 582 μm2; the long axis and short axis of the main pulmonary artery were 589±150 and 174±170 μm, respectively.ConclusionsThe improved natural development method can help to successfully establish the patent ductus arteriosus model in preterm rats.
Keywords:Patent ductus arteriosus  Animal model  Preterm  Rats
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《中国当代儿科杂志》浏览原始摘要信息
点击此处可从《中国当代儿科杂志》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏