首页 | 本学科首页   官方微博 | 高级检索  
检索        

超声联合磁共振诊断胎儿胼胝体发育不全的影像学特征分析
引用本文:黄静,陈丽荣.超声联合磁共振诊断胎儿胼胝体发育不全的影像学特征分析[J].中国CT和MRI杂志,2016(6):104-107.
作者姓名:黄静  陈丽荣
作者单位:广西柳州市人民医院超声科 广西 柳州 545007
摘    要:目的将核磁共振以及超声应用在胎儿的胼胝体发育不全筛选诊断中,分析其诊断效果和影像学特征。方法以2011年1月至2015年1月间,30例经本院超声、MRI检查后诊断为胼胝体发育不全的胎儿为对象,对全部患者的病历资料进行回顾分析,按照检查方法的不同进行组别划分,将单纯接受超声检查的15例胼胝体发育不全胎儿划分到对照组,将接受超声联合核磁共振检查的15例胼胝体发育不全胎儿划分至实验组;将两组胼胝体发育不全胎儿的检查诊断结果和随访结果相比较,对比两种检查方法的诊断准确率。同时对胎儿胼胝体发育不全的超声影像以及核磁共振影像进行分析。结果实验组胼胝体发育不全胎儿中,10例为胼胝体完全缺如,5例为胼胝体部分缺如。实验组的超声联合核磁共振诊断准确率为93.3%(14/15)。对照组胼胝体发育不全胎儿中,9例为胼胝体完全缺如,6例为胼胝体部分缺如。对照组的超声诊断准确率为86.7%(13/15)。可见实验组的诊断准确率要显著高于对照组,且组间差异P0.05。结论在产前对胎儿进行超声检查以及核磁共振检查,能够有效提高胎儿胼胝体发育不全的筛选诊断率,对胎儿胼胝体发育不全的临床诊断有着非常重要的意义。

关 键 词:胎儿胼胝体发育不全  超声  核磁共振

Analysis of Ultrasound and Magnetic Resonance Imaging in Diagnosis of Fetal Agenesis of the Corpus Callosum Imaging Features
Abstract:Objective To magnetic resonance imaging and ultrasonography in fetal agenesis of the corpus callosum screening diagnosis, analysis of the effect of diagnosis and imaging features.Methods By January 2011 to January 2015, 30 cases after the Institute of ultrasound and MRI diagnosis of corpus callosum of fetal development as the object, the medical records of all patients were retrospectively analyzed, divided into groups according to different methods to check will only accept ultrasonography of 15 cases of corpus callosum development whole fetuses divided to control group, will accept ultrasound combined with magnetic resonance imaging (MRI) of 15 patients with agenesis of the corpus callosum fetal divided to experiment group, two groups of corpus callosum body development not the fetal diagnosis results and follow-up results compared. Comparing the two kinds of inspection methods of diagnosis accurate rate. At the same time on the development of fetal corpus callosum ultrasound imaging insufficiency and magnetic resonance imaging analysis.Results The experimental group of fetal agenesis of the corpus callosum in 10 cases, 5 cases of complete agenesis of the corpus callosum, as part of the corpus callosum agenesis. The accuracy of diagnostic ultrasound and magnetic resonance of the experimental group was 93.3% (14/15). The control group of fetal agenesis of the corpus callosum in 9 cases, 6 cases of complete agenesis of the corpus callosum, as part of the corpus callosum agenesis. The diagnostic accuracy rate of control group was 86.7% (13/15). The accurate rate of diagnosis showed the experimental group was significantly higher than that of control group, and the difference of P<0.05 between groups. Conclusions In prenatal fetal of ultrasonography and magnetic resonance imaging (MRI) can effectively improve the fetal corpus callosum body development is full of screening and diagnosis rate, the clinical diagnosis of fetal corpus callosum development has a very important significance.
Keywords:Fetal Agenesis of Corpus Callosum  Ultrasound  Magnetic Resonance Imaging
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号