首页 | 本学科首页   官方微博 | 高级检索  
检索        

B超监测下放置吉妮IN IUD的临床效果观察
引用本文:周立晓,刘小英,尹华,韩定英,张云珍,曾颖,黄永红,严韶,蔡梅,吴洁,吴秀云,郑洁华,欧苗苗,欧阳伟霞,姜碧卿.B超监测下放置吉妮IN IUD的临床效果观察[J].中国计划生育学杂志,2007,15(12):737-739.
作者姓名:周立晓  刘小英  尹华  韩定英  张云珍  曾颖  黄永红  严韶  蔡梅  吴洁  吴秀云  郑洁华  欧苗苗  欧阳伟霞  姜碧卿
作者单位:1. 深圳市罗湖区计划生育服务中心,518019
2. 深圳市计划生育服务中心
3. 深圳市福田区计划生育服务中心
4. 深圳市布吉镇计划生育服务中心
基金项目:深圳市科学技术局立项资助项目
摘    要:目的:观察B超监测放置吉妮IN IUD宫内节育器的临床效果。方法:多中心随机分组在B超监测下放置吉妮IN IUD289例,TCu380A IUD 303例,分别于术后1、3、6、12、24、36个月行妇科及B超随访,以生命表方法统计结果并行显著性检验。结果:①术后疼痛TCu380A组明显高于吉妮IN组(P<0.05);术后6~36月,月经紊乱以TCu380A组为高(P<0.05)。②两组带器妊娠率均较低(吉妮IN组1.04/100妇女,TCu380A组1.32/100妇女,P>0.05);脱落率TCu380A组(6.60/100妇女)高于吉妮IN组(4.84/100妇女,P<0.05);吉妮IN组因出血和疼痛的终止率(2.77/100妇女)较TCu380A组(5.61/100妇女)低(P<0.05)。结论:吉妮INIUD具有与TCu380A IUD同样高的避孕效率,其在降低脱落率、因症取出率及副反应发生率方面优于TCu380A IUD。

关 键 词:宫内节育器  随机对照实验  B型超声波
收稿时间:2007-07-03
修稿时间:2007-10-16

Clinical Comparative Study of 592 cases of GyneFix IN and TCu380A IUD Indicated By B-ultrasonic for Three Years
ZhouLiXiao,LiuXiaoYing,YinHua,et al..Clinical Comparative Study of 592 cases of GyneFix IN and TCu380A IUD Indicated By B-ultrasonic for Three Years[J].Chinese Journal of Family Planning,2007,15(12):737-739.
Authors:ZhouLiXiao  LiuXiaoYing  YinHua  
Abstract:Objective: To study the clinical effect of GyneFix IN and TCu380A intrauterine device (IUD) indicated By B-ultrasonic after 36 months insertion. Methods: The study was a randomized multicentric comparative clinical trial. Healthy childbearing age women were allocated into GyneFix IN set(n= 289) group and TCu380A set(n= 303) group. Each IUD was inserted indicated by B-ultrasonic and followed-up at 1, 3, 6, 12, 24, 36 months after insertion . Analysis with life table method was done and statistical analysis was adopted to compare the 2 sets. Results: (1) The number of women with complaint of pain was significantly lower in GyneFix IN set than that in TCu380A set after insertion(P<0.05). The number of women with complaint of bleeding was less in GyneFix IN set at 6-36 months after insertion(P<0.05). (2) At the end of the third year ,The pregnancy rate with IUD was all low in GyneFix IN set(1.04/100 women)and in TCu380A set(1.32/100 women, P>0.05). The expulsion rate was lower in GyneFix IN set(4.84/100 women)than that in TCu380A set(6.60/100 women, P<0.05). The termination rate for bleeding and pain was lower in GyneFix IN set(2.77/100 women)than that in TCu380A set(5.61/100 women, P<0.05). Conclusion: GyneFix IN shows the same good effectiveness as TCu380A in contraceptive efficacy, and it is better than TCu380A in the lower expulsion rate, the termination rate for bleeding and pain and the side effect.
Keywords:Intrauterine device (IUD)  Randomized controlled trial  B-ultrasonic
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号