Clinical validation of the avidin/indium-111 biotin approach for imaging infection/inflammation in orthopaedic patients
Authors:Elena Lazzeri  Mario Manca  Nicola Molea  Stefano Marchetti  Vincenzo Consoli  Lisa Bodei  R Bianchi  Marco Chinol  Giovanni Paganelli  Giuliano Mariani
Institution:(1) Regional Centre of Nuclear Medicine, University of Pisa, Pisa, Italy, IT;(2) Institute of Orthopedics, University of Pisa, Pisa, Italy, IT;(3) Nuclear Medicine Service, European Institute of Oncology, Milan, Italy, IT;(4) Nuclear Medicine Service, DIMI, University of Genoa, Genoa, Italy, IT
Abstract:We report here the results of a validation study of the avidin/indium-111 biotin approach in patients with skeletal lesions. This study involved 54 patients with orthopaedic conditions: 20 patients with intermediate suspected osteomyelitis of the trunk, 19 patients with infection/inflammation of prosthetic joint replacements, and 15 patients with suspected osteomyelitis of appendicular bones. Avidin (3 mg) was injected as an i.v. bolus, followed 4 h later by 111In-biotin; imaging was acquired 30 min and 16–18 h after administration of 111In-biotin. Technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO)-labelled leucocyte scintigraphy was performed in 39/54 patients. The overall sensitivity of the avidin/111In-biotin scan was 97.7% (versus 88.9% for 99mTc-HMPAO leucocyte scintigraphy). While the diagnostic performance of avidin/111In-biotin scintigraphy was similar to that of 99mTc-HMPAO leucocyte scintigraphy in patients with prosthetic joint replacements or osteomyelitis of appendicular bones, the avidin/111In-biotin approach clearly performed better than 99mTc-HMPAO leucocyte scintigraphy in patients with suspected osteomyelitis of the trunk (100% sensitivity, specificity and accuracy versus 50% sensitivity, 100% specificity and 66.7% accuracy for 99mTc-HMPAO-leucocyte scintigraphy). These results demonstrate the feasibility of the avidin/111In-biotin approach for imaging sites of infection/inflammation in the clinical setting. Although no systematic advantages of avidin/111In-biotin scintigraphy were found versus 99mTc-HMPAO leucocyte scintigraphy, the newer scintigraphic method is more practicable and involves lower biological risk for the operators. Received 9 November 1998 and in revised form 1 February 1999
Keywords:: Avidin/streptavidin  Indium-111-biotin  Inflammation/infection  Scintigraphic imaging  Orthopaedic patients
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号