首页 | 本学科首页   官方微博 | 高级检索  
     

游离端半精密附着体义齿的支持骨表面应力分析
引用本文:王焱,米乃元,覃峰. 游离端半精密附着体义齿的支持骨表面应力分析[J]. 中山大学学报(医学科学版), 2000, 21(3): 219-222
作者姓名:王焱  米乃元  覃峰
作者单位:中山医科大学口腔医学院!广东广州510060
摘    要:【目的】研究双侧游离缺失活动义齿使用不同类型的半精密附着体时周围支持骨组织的生物力学特征。【方法】采用电阻应变测量法 ,在人体下颌骨标本上测量基牙联冠数目分别为 1,2 ,3单位的冠内及冠外半精密附着体式双侧游离缺失活动 固定联合修复体的表面应力值 ,并做统计分析。【结果】基牙数目从 1个增至 2个 ,支持骨组织应力分布明显变均匀 ,但基牙数目从 2个增至 3个时 ,应力值的改变无显著差异 ;冠内附着体在基牙周围牙槽骨上产生的总体应力较大 ,而冠外附着体在缺牙区牙槽嵴和近缺隙侧基牙远中颈部牙槽嵴上产生的应力较大。【结论】在设计游离端附着体义齿时 ,基牙联冠不宜跨度过大 ;附着体类型的选择应根据缺牙区牙槽嵴及远中基牙牙体、牙周条件酌情而定。

关 键 词:义齿  精密附着式  牙应力分析  义齿设计  义齿  局部  可摘
修稿时间:1999-08-05

The Surface Stress Analysis of the Supporting Bone Tissue of Distal Extension Denture Retained with Semi precision Attachment
WANG Yan,MI Nai yuan,QIN Feng,LIUFU Guan ping,CHEN Jin an. The Surface Stress Analysis of the Supporting Bone Tissue of Distal Extension Denture Retained with Semi precision Attachment[J]. Journal of Sun Yatsen University(Medical Sciences), 2000, 21(3): 219-222
Authors:WANG Yan  MI Nai yuan  QIN Feng  LIUFU Guan ping  CHEN Jin an
Abstract:Objectivel To measure the surface stress of the periodontal supporting bone of bilateral distal extension removable partial denture retained by intracoronal or extracoronal attachment and with different number of abutments by strain gauge. Method Strain gauges were bonded in the human mandible to measure the surface stress of bilateral distal extension removable partial denture retained by intracoronal or extracoronal attachments and with different number of abutments. Results Increasing the splinted abutment number from 1 to 2, the stress distribution significantly became more evenly, but increasing the number from 2 to 3, there were no significant changes in stress values. Intracoronal attachment generally produced higher stress in the alveolar bone around the abutments than the extracoronal attachment, but extracoronal attachment produced higher stress in the edentulous alveolar crest and distal cervical alveolar bone of the distal abutment than the intracoronal attachment. Conclusion While designing the attachment retained distal extension removable partial denture, the splinted abutment span should not be too long. The selection of intracoronal or extracoronal attachment should be decided by different situations of the periodontal condition of distal abutment and the edentulous alveolar crest.
Keywords:denture   precision attachment  denture stress analysis  denture design  denture   partial   removable
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号