首页 | 本学科首页   官方微博 | 高级检索  
     


Evaluation of the PET component of simultaneous [18F]choline PET/MRI in prostate cancer: comparison with [18F]choline PET/CT
Authors:Axel Wetter  Christine Lipponer  Felix Nensa  Philipp Heusch  Herbert Rübben  Jens-Christian Altenbernd  Thomas Schlosser  Andreas Bockisch  Thorsten Pöppel  Thomas Lauenstein  James Nagarajah
Affiliation:1. Department of diagnostic and interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
2. Department of diagnostic and interventional Radiology, University Dusseldorf, Medical Faculty, Dusseldorf, Germany
3. Department of Urology and pediatric Urology, University Hospital Essen, Essen, Germany
4. Department of Nuclear Medicine, University Hospital Essen, Essen, Germany
Abstract:

Purpose

The aim of this study was to evaluate the positron emission tomography (PET) component of [18F]choline PET/MRI and compare it with the PET component of [18F]choline PET/CT in patients with histologically proven prostate cancer and suspected recurrent prostate cancer.

Methods

Thirty-six patients were examined with simultaneous [18F]choline PET/MRI following combined [18F]choline PET/CT. Fifty-eight PET-positive lesions in PET/CT and PET/MRI were evaluated by measuring the maximum and mean standardized uptake values (SUVmax and SUVmean) using volume of interest (VOI) analysis. A scoring system was applied to determine the quality of the PET images of both PET/CT and PET/MRI. Agreement between PET/CT and PET/MRI regarding SUVmax and SUVmean was tested using Pearson’s product-moment correlation and Bland-Altman analysis.

Results

All PET-positive lesions that were visible on PET/CT were also detectable on PET/MRI. The quality of the PET images was comparable in both groups. Median SUVmax and SUVmean of all lesions were significantly lower in PET/MRI than in PET/CT (5.2 vs 6.1, p?p?max of PET/CT and PET/MRI (R?=?0.86, p?mean of PET/CT and PET/MRI (R?=?0.81, p?max of PET/CT vs PET/MRI and ?1.12 to +2.23 between SUVmean of PET/CT vs PET/MRI.

Conclusion

PET image quality of PET/MRI was comparable to that of PET/CT. A highly significant correlation between SUVmax and SUVmean was found. Both SUVmax and SUVmean were significantly lower in [18F]choline PET/MRI than in [18F]choline PET/CT. Differences of SUVmax and SUVmean might be caused by different techniques of attenuation correction. Furthermore, differences in biodistribution and biokinetics of [18F]choline between the subsequent examinations and in the respective organ systems have to be taken into account.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号