首页 | 本学科首页   官方微博 | 高级检索  
     


Localization of a Colovesical Fistula Using a Retrograde Guide-Wire: Report of a Case
Authors:Paolo Aurello  Claudia Cicchini  Francesco D’Angelo  Giovanni Ramacciato  Andrea Giuliani
Affiliation:(1) Department of Surgery "ldquo"Pietro Valdoni"rdquo", University of Rome "ldquo"La Sapienza"rdquo", via Cairano 6, 00177 Rome, Italy
Abstract:We describe an unconventional method of localizing a colovesical fistula by using a guide-wire, successfully carried out in a 45-year-old man with recurrent dysuria, pneumaturia, and suprapubic tenderness. First, we performed a cystoscopy to establish the fistulous tract in the bladder and passed the guide-wire through it. Next, we performed a colonoscopy, and the guide-wire was identified and brought out through the anus. This created a wire loop through the fistula. The transparietal cathether enabled us to detect the exact fistulous tract at laparotomy, making it possible to resect the inflamed colon and identify and resect the fistulous opening on the vesical wall. This technique allowed for a safer resection and a shorter operation time.
Keywords:Diverticulitis  Colovesical fistula  Surgery  Guide-wire
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号