首页 | 本学科首页   官方微博 | 高级检索  
检索        


Misfit and microleakage of implant-supported crown copings obtained by laser sintering and casting techniques,luted with glass-ionomer,resin cements and acrylic/urethane-based agents
Authors:Raquel Castillo-Oyagüe  Christopher D Lynch  Andrés S Turrión  José F López-Lozano  Daniel Torres-Lagares  María-Jesús Suárez-García
Institution:1. Department of Buccofacial Prostheses, Faculty of Odontology, Complutense University of Madrid (UCM), Pza. Ramón y Cajal, n° 3, 28040, Madrid, Spain;2. Tissue Engineering and Reparative Dentistry, School of Dentistry, Cardiff, UK;3. Department of Stomatology, Faculty of Odontology, University of Seville (US), C/Avicena, s/n, 41009, Seville, Spain
Abstract:ObjectivesThis study evaluated the marginal misfit and microleakage of cement-retained implant-supported crown copings.MethodsSingle crown structures were constructed with: (1) laser-sintered Co–Cr (LS); (2) vacuum-cast Co–Cr (CC) and (3) vacuum-cast Ni–Cr–Ti (CN). Samples of each alloy group were randomly luted in standard fashion onto machined titanium abutments using: (1) GC Fuji PLUS (FP); (2) Clearfil Esthetic Cement (CEC); (3) RelyX Unicem 2 Automix (RXU) and (4) DentoTemp (DT) (n = 15 each). After 60 days of water ageing, vertical discrepancy was SEM-measured and cement microleakage was scored using a digital microscope. Misfit data were subjected to two-way ANOVA and Student–Newman–Keuls multiple comparisons tests. Kruskal–Wallis and Dunn's tests were run for microleakage analysis (α = 0.05).ResultsRegardless of the cement type, LS samples exhibited the best fit, whilst CC and CN performed equally well. Despite the framework alloy and manufacturing technique, FP and DT provide comparably better fit and greater microleakage scores than did CEC and RXU, which showed no differences.ConclusionsDMLS of Co–Cr may be a reliable alternative to the casting of base metal alloys to obtain well-fitted implant-supported crowns, although all the groups tested were within the clinically acceptable range of vertical discrepancy. No strong correlations were found between misfit and microleakage. Notwithstanding the framework alloy, definitive resin-modified glass-ionomer (FP) and temporary acrylic/urethane-based (DT) cements demonstrated comparably better marginal fit and greater microleakage scores than did 10-methacryloxydecyl-dihydrogen phosphate-based (CEC) and self-adhesive (RXU) dual-cure resin agents.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号