首页 | 本学科首页   官方微博 | 高级检索  
检索        


Influence of various irradiation processes on the mechanical properties and polymerisation kinetics of bulk-fill resin based composites
Authors:Nicoleta Ilie  Andreas Keßler  Jürgen Durner
Institution:1. Department of Operative/Restorative Dentistry, Periodontology and Pedodontics, Ludwig-Maximilians-University of Munich, Goethestr. 70, 80336 Munich, Germany;2. Walther-Straub-Institute of Pharmacology and Toxicology, Nussbaumstr. 26, 80336 Munich, Germany
Abstract:ObjectivesTo assess the effect of irradiation time and distance of the light tip on the micro-mechanical properties and polymerisation kinetics of two bulk-fill resin-based composites at simulated clinically relevant filling depth.MethodsMicro-mechanical properties (Vickers hardness (HV), depth of cure (DOC) and indentation modulus (E)) and polymerisation kinetics (real-time increase of degree of cure (DC)) of two bulk-fill resin-based composites (Tetric EvoCeram® Bulk Fill, Ivoclar Vivadent and x-tra base, Voco) were assessed at varying depth (0.1–6 mm in 100 μm steps for E and HV and 0.1, 2, 4 and 6 mm for DC), irradiation time (10, 20 or 40 s, Elipar Freelight2) and distances from the light tip (0 and 7 mm). Curing unit's irradiance was monitored in 1 mm steps at distances up to 10 mm away from the light tip on a laboratory-grade spectrometer.ResultsMultivariate analysis (α = 0.05), Student's t-test and Pearson correlation analysis were considered. The influence of material on the measured mechanical properties was significant (η2 = 0.080 for E and 0.256 for HV), while the parameters irradiation time, distance from the light tip and depth emphasise a stronger influence on Tetric EvoCeram® Bulk Fill. The polymerisation kinetics could be described by an exponential sum function, distinguishing between the gel and the glass phase. The above mentioned parameters strongly influenced the start of polymerisation (gel phase), and were of less importance for the glass phase.ConclusionsBoth materials enable at least 4 mm thick increments to be cured in one step under clinically relevant curing conditions.Clinical significanceThe susceptibility to variation in irradiance was material dependent, thus properties measured under clinically simulated curing conditions might vary to a different extent from those measured under ideal curing conditions.
Keywords:Bulk-fill resin based composites  Irradiance  Hardness  Modulus of elasticity  Polymerisation kinetic
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号