首页 | 本学科首页   官方微博 | 高级检索  
检索        

电感耦合等离子体质谱法测定猪肉中总砷的不确定度
引用本文:吴思霖,王欣美,于建,潘晨,顾颂青,陆明.电感耦合等离子体质谱法测定猪肉中总砷的不确定度[J].上海预防医学,2020,32(5):387-391.
作者姓名:吴思霖  王欣美  于建  潘晨  顾颂青  陆明
作者单位:上海市食品药品检验所,上海201203;上海市食品药品检验所,上海201203;上海市食品药品检验所,上海201203;上海市食品药品检验所,上海201203;上海市食品药品检验所,上海201203;上海市食品药品检验所,上海201203
基金项目:科技部食品重大课题资助项目
摘    要:【目的】对基于GB 5009.11—2014《食品安全国家标准食品中总砷及无机砷的测定》方法测定猪肉中总砷的不确定度,探讨各不确定度分量的影响,以提高实验结果的准确性。【方法】对测量过程中影响测定结果的不确定度来源包括重复性测量、样品称量、样品稀释、标准品质量浓度、标准曲线等进行不确定度评估。采用A类评定评估测定重复性测量引入的不确定度,由其他因素引起的不确定度采用B类评定评估。根据各分量计算相对合成标准不确定度以及相对扩展不确定度,探讨各不确定度分量对测定结果的影响。【结果】按照不确定度贡献由大到小依次是样品中标准品质量浓度、标准曲线、重复性测定、样品称量、样品稀释过程。相对合成标准不确定度为0.0405,相对扩展不确定度为0.081(k=2)。【结论】实验测量中标准品质量分数影响较大,应严格规范标准品溶液稀释的操作,简化稀释步骤,提高测量结果的准确性。

关 键 词:总砷  不确定度  电感耦合等离子体质谱法(ICP-MS)  猪肉

Uncertainty evaluation of total arsenic in pork by inductively coupled plasma mass spectrometry
WU Si-lin,WANG Xin-mei,YU Jian,PAN Chen,GU Song-qing,LU Ming.Uncertainty evaluation of total arsenic in pork by inductively coupled plasma mass spectrometry[J].Shanghai Journal of Preventive Medicine,2020,32(5):387-391.
Authors:WU Si-lin  WANG Xin-mei  YU Jian  PAN Chen  GU Song-qing  LU Ming
Institution:(Shanghai Institute for Food and Drug Control,Shanghai 201203,China)
Abstract:Objective]To make uncertainty evaluation of total arsenic in pork by using the national food safety standard“GB 5009.11-2014 determination of total arsenic and inorganic arsenic in food”,and discuss the influence of each uncertainty component on the determination results so as to improve the accuracy of the experimental results.Methods]The uncertainty sources that affected the measurement results in the measurement process,including repeatability measurement,sample weighing,sample dilution,standard concentration,standard curve and so on were evaluated.The uncertainty introduced by the repeatability measurement was evaluated by class A,the uncertainty caused by other factors was evaluated by class B,and the phase was calculated according to each component.The synthetic standard uncertainty and the relative expanded uncertainty were discussed,and so were the influence of the uncertainty components on the measurement results.Results]According to the contribution of uncertainty from large to small was the sample standard concentration,standard curve,repeatability determination,sample weighing and sample dilution.The calculated relative composite standard uncertainty was 0.0405,and the relative expanded uncertainty was 0.081(k=2).Conclusion]The experimental results show that the concentration of standard substance has a great influence on the measurement process,so it is necessary to standardize the dilution process and simplify the dilution procedure to improve the accuracy of measurement results.
Keywords:total arsenic  uncertainty  inductively coupled plasma mass spectrometry(ICP-MS)  pork
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏