Rotator cuff sonography: a reassessment |
| |
Authors: | Brandt, TD Cardone, BW Grant, TH Post, M Weiss, CA |
| |
Affiliation: | Department of Diagnostic Radiology, Michael Reese Hospital and Medical Center, Chicago, IL 60616. |
| |
Abstract: | This study is both a retrospective and prospective evaluation of the clinical usefulness of shoulder sonography. Ninety-eight patients suspected of having rotator cuff tears underwent sonography of both shoulders. Sixty-two patients underwent double-contrast arthrography performed on the same day as sonography, and 38 patients underwent surgery after sonography. A comparison of the results from ultrasound and arthrography, using published diagnostic criteria, demonstrated a sensitivity of 75% and a specificity of 43% for detection of a rotator cuff tear. In this study, use of more restricted criteria, a subset of the published criteria, yielded a sensitivity of 68% and a specificity of 90%. A comparison of sonography with surgery, using this study's criteria, demonstrated a sensitivity of 57% and a specificity of 76%. This report shows that shoulder sonography is less reliable than previously reported and appears to have a very limited role in the evaluation of rotator cuff injuries. |
| |