首页 | 本学科首页   官方微博 | 高级检索  
     

异种生物骨钉界面的成骨能力
引用本文:谭新宇,章莹,任志坚,黄高潮,林茂群. 异种生物骨钉界面的成骨能力[J]. 中国临床康复, 2011, 0(42): 7796-7800
作者姓名:谭新宇  章莹  任志坚  黄高潮  林茂群
作者单位:解放军广州军区广州总医院骨科医院创伤骨科,广东省广州市510660
摘    要:背景:牛皮质骨作为异种皮质骨材料应用最为广泛,但其免疫原性反应严重,从而可能导致内固定失败。目的:观察3种不同皮质骨螺钉在动物体内的转归,及不同材料骨钉的生物力学性能以及免疫原性反应差异。方法:脱脂、脱细胞、灭菌及诱导活性修饰处理制备牛皮质骨生物界面螺钉及普通方式处理后的消毒牛骨钉及消毒羊骨钉。再将3种骨钉植入健康18只山羊股骨中段进行生物学性能观察。结果与结论:Lane组织学评分生物界面骨螺钉〉消毒羊骨钉〉消毒牛骨钉(P〈0.01)。生物力学实验行初始界面刚度载荷及界面刚度比较,3组差异无显著性意义(P〉0.05);12周时,生物界面骨螺钉〉两组消毒钉(P〈0.05);24周时,生物界面骨螺钉〉消毒羊骨钉〉消毒牛骨钉(P〈0.01)。提示,生物界面骨螺钉的初始力学性能不低于消毒牛骨,且能较长时间保持稳定的力学性能;生物界面骨螺钉具有一定的成骨作用,与宿主骨组织结合后,产生了更强的界面力学性能。

关 键 词:骨移植  异种骨  骨螺钉  病理组织学  界面应力  界面刚度

Osteogenic ability of heterogeneous biological bone screw
Tan Xin-yu,Zhang Ying,Ren Zhi-jian,Huang Gao-chao,Lin Mao-qun. Osteogenic ability of heterogeneous biological bone screw[J]. Chinese Journal of Clinical Rehabilitation, 2011, 0(42): 7796-7800
Authors:Tan Xin-yu  Zhang Ying  Ren Zhi-jian  Huang Gao-chao  Lin Mao-qun
Affiliation:Department of Traumatic Orthopedics, Orthopedics Hospital, Guangzhou General Hospital of Guangzhou Military Command, Guangzhou 510660, Guangdong Province, China
Abstract:BACKGROUND: Bovine cortical bone as a heterogeneous cortical bone material has been most widely used, but the immunogenic reactions are serious, which may lead to fixation failure. OBJECTIVE: To observe the outcomes of three different cortical bone screws in vivo as well as the biomechanical properties and immunogenicity responses of different bone screws. METHODS: Bovine cortical bone bio-interference screw, bovine bone nail and sheep bone nail were implanted into the femur of 18 healthy adult goats to observe their biological properties. RESULTS AND CONCLUSION: Lane histological scores were bovine cortical bone bio-interference screw sheep bone nail bovine bone nail (P 0.01). Biomechanical experiments showed that the initial interface load and interface stiffness had no differences among three different screws (P 0.05). At 12 weeks, the interface load and stiffness was higher for bovine cortical bone bio-interference screw than the other two screws; at 24 weeks, the interface load and stiffness was bovine cortical bone bio-interference screw sheep bone nail bovine bone nail (P 0.01). It indicated that the initial bio-mechanical properties of bio-interference screw was not less than those of sterilized bovine bone, which could be maintained for a long time; after the bio-interference screw was implanted into the host bone tissue, stronger interference mechanical properties produced.
Keywords:
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号