Delayed obturator artery rupture: a complication of high-voltage electrical injury |
| |
Authors: | Chuang Shiow Shuh Yu Chung Chih |
| |
Affiliation: | The Burn Center, Department of Plastic and Reconstructive Surgery, Chang Gung Memorial Hospital, 5, Fu-Shin Street, Kwei-Shan, 333, Taoyuan, Taiwan |
| |
Abstract: | Electrical burns cause damage to the cardiovascular system through different mechanisms. Immediate cardiac arrhythmia is one of the common consequences. A large vessel blow out due to an electrical burn is rarely documented. It is often undetected due to its "silent" symptoms. This article reports a delayed obturator artery rupture in a 32-year-old male patient 6 weeks after he sustained severe high-voltage electrical burns. The vessel injury was treated with computed tomography (CT)-aided embolization. The patient recovered to an ambulatory status 10 weeks after the injury. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|