Simultaneous extraction of hepatitis C virus (HCV), hepatitis B virus, and HIV-1 from plasma and detection of HCV RNA by a reverse transcriptase-polymerase chain reaction assay designed for screening pooled units of donated blood |
| |
Authors: | R. Sun W. Schilling H. Jayakar J. Ku J. Wang M. Rosenstraus J. Spadoro |
| |
Affiliation: | Roche Molecular Systems, Inc., Somerville, New Jersey 08876, USA. |
| |
Abstract: | BACKGROUND: Testing for viral nucleic acids should reduce the residual risk of transmitting viral infections by transfusion of blood components. The AmpliScreen Hepatitis C (HCV) Test, Version 2.0, was designed for screening pools composed of samples from individual units of blood or plasma. STUDY DESIGN AND METHODS: An ultracentrifugation step during sample processing simultaneously extracts and concentrates HCV, HIV type 1, and hepatitis B virus particles from plasma. An HCV internal control RNA serves as an extraction and amplification control for each processed sample. Processed samples are amplified by reverse transcriptase polymerase chain reaction and detected by hybridization of the amplified products to HCV- and internal-control-specific oligonucleotide probes. Plasma samples containing known quantities of HCV were used to evaluate analytical sensitivity and precision. RESULTS: The analytical sensitivity of the test was 25 IU of HCV per mL of pooled plasma; all HCV genotypes were detected with similar efficiency. The test did not react with other blood-borne viruses. The within-run and total coefficients of variation were 1.3-13.0 percent and 1.7-22.0 percent, respectively, with low copy samples producing the more variable results. The test performed well using plasma collected in either EDTA, ACD, or PPT Vacutainer tubes. Plasma samples containing elevated levels of hemoglobin, albumin, triglycerides, or bilirubin did not interfere with the test. The test detected HCV RNA 23 to 32 days prior to seroconversion for four of the five seroconversion panels tested. CONCLUSION: The AmpliScreen HCV Test, Version 2.0 provides a reproducible and specific method for screening pooled blood units for HCV. Theoretically, this test has sufficient sensitivity to detect a single infected unit containing 2.4 x 10(3) IU of HCV per mL in a pool with 95 uninfected units and should reduce the window period by at least 20 to 30 days. |
| |
Keywords: | Av-HRP = avidin horseradish peroxidase geq = genome equivalents HBV = hepatitis B virus HCV = hepatitis C virus HIV-1 = human immunodeficiency virus type 1 NIBSC = National Institute of Biological Standards Committee PCR = polymerase chain reaction RT = reverse transcriptase WHO = World Health Organization |
|
|