Laparoscopic peritoneal dialysis catheter insertion using a Quinton percutaneous insertion kit.
Authors:Stephen P Haggerty  Tallal M Zeni  Mike Carder  Constantine T Frantzides
Institution:Department of Surgery, Evanston Northwestern Healthcare, Evanston, Illinois, USA. haggertys@ameritech.net
Abstract:OBJECTIVE: We assessed a unique technique of laparoscopic peritoneal dialysis (PD) catheter insertion which can minimize catheter dysfunction. METHODS: We performed a retrospective review of patients undergoing laparoscopic PD catheter placement with a Quinton percutaneous insertion kit between July 2000 and December 2004. RESULTS: Thirty-one catheters were placed laparoscopically. The mean operating time was 52 minutes. Adhesiolysis was required in 9 (29%) and omentectomy or omentopexy in 3 (10%) cases. Late complications included catheter dysfunction in 2 patients (6.5%), debilitating abdominal pain requiring catheter removal in 1 patient, and 1 trocar-site hernia. The mean follow-up was 17 months. CONCLUSIONS: Laparoscopic PD catheter insertion using a Quinton percutaneous insertion kit is safe, reproducible, and effective. It facilitates placement of the catheter tip into the pelvis and allows adhesiolysis, omentectomy, or omentopexy when necessary. Utilization of this technique results in a low rate of PD catheter dysfunction.
Keywords:Minimally invasive surgery  Laparoscopy  Continuous ambulatory peritoneal dialysis  Catheter  In-dwelling  Catheter dysfunction