Optimal Covering Material for Stent-Grafts Placed in the Portal Vein in a Canine Model |
| |
Authors: | Seigo Ishii Morio Sato Tetsuo Sonomura Katsuyuki Yamada Hirohiko Tanihata Hime Ishikawa Masaki Terada Shinya Sahara Nobuyuki Kawai Masashi Kimura Ichiro Mori |
| |
Affiliation: | (1) Department of Radiology, Wakayama Medical University, 811-1, Kimiidera, Wakayama Shi Wakayama, 641-8510, Japan;(2) Department of 2nd Pathology, Wakayama Medical University, 811-1, Kimiidera, Wakayama Shi Wakayama, 641-8510, Japan |
| |
Abstract: | Purpose We evaluated the suitability of Dacron, polytetrafluoroethylene (PTFE), and small intestinal submucosa (SIS) as a covering material for stent-grafts placed in the portal vein as compared with a bare stent. Methods Using 24 beagle dogs, either bare stents or stent-grafts covered with Dacron, PTFE, or SIS were placed in the main trunk of the portal vein in 6 animals each. Portography was performed immediately after stent placement, and at 2, 4, and 12 weeks thereafter. Next, the extracted stents or stent-grafts were examined histopathologically. Neointimal thickness adjacent to the stent wire and at the midportion between the stent wires was compared among the groups. Then, the neointimal thickness at the sub- and supragraft sites was compared between each stent-graft group. Serial changes in the histologic features of the thickened neointima were also investigated. Results No significant difference was noted in the mean stenotic ratio of the portal vein diameter between the bare stent and PTFE groups, whereas it was significantly higher in the Dacron and SIS groups compared with the bare stent group. In neither of the studies on neointimal thickness adjacent to the stent wire and at the midportion between the stent wires were any significant differences noted between the neointimal thickness of the bare stent group and the sum of the neointimal thickness of the PTFE group, whereas the sum of the neointimal thickness of the Dacron and SIS groups was significantly greater than that of the bare stent group at both sites. In the comparison of the supragraft neointimal thickness, the SIS group showed significantly greater thickness than the PTFE group, while the difference between the Dacron and PTFE groups was not significant. In the comparison of the subgraft neointimal thickness, the Dacron and SIS groups showed significantly greater thickness than the PTFE group. Conclusion The present results indicate that of the three covering materials examined here, PTFE is the most suitable material for grafts placed in the portal vein. |
| |
Keywords: | Grafts Interventional procedure Liver neoplasms Portal vein thrombosis Stents and prostheses |
本文献已被 PubMed SpringerLink 等数据库收录! |
|