Comparison of multiple imaging modalities for measuring orifice diameter and selecting occluder size in patients undergoing left atrial appendage closure
Authors:Kandi Zhang  Jing Zhou  Tiantian Zhang  Zongqi Zhang  Shanliang Jin  Qing He  Junfeng Zhang
Affiliation:1. Department of Cardiology, Ninth People''s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai China ; 2. Department of Anesthesiology, Ninth People''s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai China
Abstract:BackgroundLeft atrial appendage (LAA) closure (LAAC) can safely and effectively prevent stroke events caused by atrial fibrillation. However, the structure of the LAA is highly variable among individuals, and the optimal method for obtaining measurements remains unknown.HypothesisWe aimed to study the accuracy of left atrial computed tomography angiography (CTA), three‐dimensional (3D) reconstruction using CTA, two‐dimensional transesophageal echocardiography (2D‐TEE), and digital subtraction angiography (DSA) for measuring the diameter of the LAA and compare their value for selecting occluder size.MethodsWe retrospectively evaluated data for 148 patients with nonvalvular atrial fibrillation who underwent successful LAAC. CTA and 2D‐TEE of the left atrium and pulmonary vein were performed before LAAC. We performed 3D reconstruction of the left atrium and LAA using Mimics and 3‐matics software. DSA of the LAA was performed during surgery.ResultsValues measured via CTA 3D reconstruction were significantly higher than those measured using other methods. DSA‐measured values were significantly lower than those measured via CTA and CTA 3D reconstruction. Occluder size was positively correlated with LAA orifice diameter. The differences between occluder size and DSA, 2D‐TEE, CTA, CTA 3D reconstruction measurements were 4.96 ± 2.58, 4.64 ± 2.50, 4.04 ± 1.37, and 2.92 ± 1.38 mm, respectively. Intraclass correlation coefficients for these methods were −.067, .006, .241, and .519, respectively.ConclusionCTA 3D reconstruction provides the best correlation and consistency between the measured LAA orifice diameter and occluder size. Adding 2–4 mm to the maximum LAA orifice diameter based on 3D‐CTA may aid in selecting the appropriate WATCHMAN device.
Keywords:3D reconstruction   atrial fibrillation   left atrial appendage occlusion   occluder size
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号