摘    要:受检者静脉注射99mTc-DTPA(3~8mci),使用r相机,采集6分钟,利用Gates法计算肾小球滤过率(GFR).重复性实验l0例GFR(11~101.9ml/min),结果两均数分别是63.35ml/min,62.55ml/min,P=0.47,两均数间均无差别,相关性很好,r=0.986,15例GFR与肌酐清除率(CCr)比较,GFR(8.1~101.7ml/min).CCr(5.2~97.4ml/min)回归方程是CCr=-4.638+0.95GFR,相关性很好,r=0.983

关 键 词:肾小球滤过率,肌酐,研究

Rapid Method Determination of GlomerularFiltration Rate (GFR) by SPECT DuMinghua
Liu Lu,Wang Ping..Rapid Method Determination of GlomerularFiltration Rate (GFR) by SPECT DuMinghua[J].Modern Medical JOurnal,1994(4).
Authors:Liu Lu  Wang Ping
Abstract:his papar discusses the computation ofGFR by Gates niethod, with 99m Tc - DTPAvein inJection and r camera acqisition 6 min-utes. Result of reproducibility of 10 sample isobtained exellently correlative (r= 0. 986 ,P<0.001 GFR2=0. 65 0. 998GFR). The meanvalue is 63. 35ml/min, 62. 55ml/min, respec-tively , and no significant difference is observedbetween two GFR. A close correlation is ob-served between creatinine clearance rate(CCrfrom 5. 2 to 97. 4ml/min and GFR 8.1-101ml/min)by Gates'formula with r value of 0.983.p<0.001 and CCr-4. 638 0.957GFR.