离子选择性电极法测定卡托普利片含量 |
| |
引用本文: | 程会云,陈晓红,刘占厚,朱俊博,陈湘宏.离子选择性电极法测定卡托普利片含量[J].中国当代医药,2009,16(5):33-34. |
| |
作者姓名: | 程会云 陈晓红 刘占厚 朱俊博 陈湘宏 |
| |
作者单位: | 青海大学医学院药学系,青海西宁,810001 |
| |
摘 要: | 目的:建立离子选择性电极法测定卡托普利片含量的新方法。方法:卡托普利结构含有-SH,呈酸性,与碱作用生成RS-硫离子选择性电极对其产生响应。结果:电极响应的电位值与-lgRS-]符合能斯特方程。能斯特响应范围为1.0×10^-6~1.0×10^-2mol/L(r=0.9998),平均回收率为99.4%,RSD=0.29%(n=6)。结论:本法设备仪器简单,分析快速,专属性强。
|
关 键 词: | 离子选择性电极 卡托普利片 含量 |
Determination of the content in Captopril Tablets with ion selective electrode |
| |
Authors: | CHENG Hui-Yun CHEN Xiao-hong LIU Zhan-hou ZHU Jun-bo CHEN Xiang-hong |
| |
Institution: | (Department of Pharmaceutical Sciences School of medicines Qinghai University, Xining 810001, China) |
| |
Abstract: | Objective: A new method was established for the determination of Captopril with ion selective electrode. Methods: Based on the thiohydroxy group (-SH) in Captopril can rect with base and produce RS-,Results: The linear relationship between E and - lgRS-] was held in the range of 1.0×10^-6~1.0×10^-2mol/L(r=0.9998).The average recovery was 99.4% ,RSD=0.29%(n=6). Conclusion:This method is simple,convenient,specific and is suitable for the quality control of Captopril tablets. |
| |
Keywords: | Ionselective electrode Captopril tablets Content |
本文献已被 维普 万方数据 等数据库收录! |
|