首页 | 本学科首页   官方微博 | 高级检索  
检索        


Visual outcomes after accommodating intraocular lens implantation
Authors:Macsai Marian S  Padnick-Silver Lissa  Fontes Bruno M
Institution:Division of Opthalmology, Evanston Northwestern Healthcare, Evanston, Illinois 60026, USA. mmacsai@enh.org
Abstract:PURPOSE: To evaluate and compare the visual outcomes and accommodative amplitude in cataract patients after implantation of the Crystalens intraocular lens (IOL) (Eyeonics) versus standard monofocal IOLs. SETTING: Ten clinics in a nationwide multicenter study in the United States. METHODS: A multicenter comparative interventional case series with masked randomized postoperative examination of 224 eyes of 112 patients was performed by a single observer. Patients were divided into 2 groups (56 patients; 112 eyes each) depending on which IOL was implanted (Crystalens or monofocal). Accommodation was measured using 1 objective (dynamic retinoscopy) and 2 subjective methods (defocus and near point of accommodation). Visual acuity measurements were performed under the same conditions with standard visual acuity charts. RESULTS: Uncorrected monocular near vision was significantly better in the Crystalens group than in the standard monofocal group, with 101 of 112 eyes (90%) and 17 of 112 (15%), respectfully, reading J3 or better postoperatively. All 56 Crystalens patients had a binocular uncorrected near visual acuity of J3 or better compared with 16 of 56 (29%) standard monofocal patients. The mean postoperative monocular (0.85 +/- 0.30 SD] versus 0.70 +/- 0.19, P<.01) and binocular (1.16 +/- 0.17 versus 1.01 +/- 0.14, P<.01) distance uncorrected visual acuities were also better in the Crystalens group than in the control group. All patients in the study achieved a corrected distance visual acuity of 20/20 or better. Measures of accommodation were significantly higher in Crystalens patients than in the monofocal IOL patients (dynamic retinoscopy 2.42 +/- 0.39 diopters D] versus 0.91 +/- 0.24 D, P<.01; monocular defocus 1.74 +/- 0.48 D versus 0.75 +/- 0.25 D, P<.01; monocular near point of accommodation 9.5 +/- 3.1 inches versus 34.7 +/- 9.8 inches, P<.01). Perceived accommodation (5.79 D) was significantly greater than the measured accommodation (1.96 to 2.42 D) in Crystalens patients (paired t test, P<.01). CONCLUSIONS: The Crystalens IOL provided better uncorrected near and distance visual outcomes than standard monofocal IOLs in all analyses performed. Patients perceived a greater accommodation than measured. Understanding why this occurred could lead to valuable advances in accommodating IOL technology.
Keywords:
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号