首页 | 本学科首页   官方微博 | 高级检索  
检索        


Small bowel toxicity after high dose spot scanning-based proton beam therapy for paraspinal/retroperitoneal neoplasms
Authors:Dr RA Schneider  V Vitolo  F Albertini  T Koch  C Ares  A Lomax  G Goitein  EB Hug
Institution:1. Center for Proton Therapy, Paul Scherrer Institute, 5232, Villigen PSI, Germany
2. Fondazione CNAO, Pavia, Italy
3. ProCure Proton Therapy Centers, New York, USA
Abstract:

Purpose

Mesenchymal tumours require high-dose radiation therapy (RT). Small bowel (SB) dose constraints have historically limited dose delivery to paraspinal and retroperitoneal targets. This retrospective study correlated SB dose–volume histograms with side-effects after proton radiation therapy (PT).

Patients and methods

Between 1997 and 2008, 31 patients (mean age 52.1 years) underwent spot scanning-based PT for paraspinal/retroperitoneal chordomas (81?%), sarcomas (16?%) and meningiom (3?%). Mean total prescribed dose was 72.3 Gy (relative biologic effectiveness, RBE) delivered in 1.8–2 Gy (RBE) fractions. Mean follow-up was 3.8 years. Based on the pretreatment planning CT, SB dose distributions were reanalysed.

Results

Planning target volume (PTV) was defined as gross tumour volume (GTV) plus 5–7 mm margins. Mean PTV was 560.22 cm3. A mean of 93.2?% of the PTV was covered by at least 90?% of the prescribed dose. SB volumes (cm3) receiving doses of 5, 20, 30, 40, 50, 60, 70, 75 and 80 Gy (RBE) were calculated to give V5, V20, V30, V40, V50, V60, V70, V75 and V80 respectively. In 7/31 patients, PT was accomplished without any significant SB irradiation (V5?=?0). In 24/31 patients, mean maximum dose (Dmax) to SB was 64.1 Gy (RBE). Despite target doses of >?70 Gy (RBE), SB received >?50 and >?60 Gy (RBE) in only 61 and 54?% of patients, respectively. Mean SB volumes (cm3) covered by different dose levels (Gy, RBE) were: V20 (n?=?24): 45.1, V50 (n?=?19): 17.7, V60 (n?=?17): 7.6 and V70 (n?=?12): 2.4. No acute toxicity ≥ grade 2 or late SB sequelae were observed.

Conclusion

Small noncircumferential volumes of SB tolerated doses in excess of 60 Gy (RBE) without any clinically-significant late adverse effects. This small retrospective study has limited statistical power but encourages further efforts with higher patient numbers to define and establish high-dose threshold models for SB toxicity in modern radiation oncology.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏