A novel scheme for the validation of an automated classification method for epileptic spikes by comparison with multiple observers
Authors:Niraj K. Sharma  Carlos Pedreira  Maria Centeno  Umair J. Chaudhary  Tim Wehner  Lucas G.S. França  Tinonkorn Yadee  Teresa Murta  Marco Leite  Sjoerd B. Vos  Sebastien Ourselin  Beate Diehl  Louis Lemieux
Affiliation:1. Dept. of Clinical and Experimental Epilepsy, UCL Institute of Neurology, London, United Kingdom;2. Dept. of Experimental Psychology, University of Oxford, Oxford, United Kingdom;3. Translational Imaging Group, Centre for Medical Image Computing, UCL, London, United Kingdom;4. Dementia Research Centre, UCL Institute of Neurology, London, United Kingdom
Abstract:

Objective

To validate the application of an automated neuronal spike classification algorithm, Wave_clus (WC), on interictal epileptiform discharges (IED) obtained from human intracranial EEG (icEEG) data.

Method

Five 10-min segments of icEEG recorded in 5 patients were used. WC and three expert EEG reviewers independently classified one hundred IED events into IED classes or non-IEDs. First, we determined whether WC-human agreement variability falls within inter-reviewer agreement variability by calculating the variation of information for each classifier pair and quantifying the overlap between all WC-reviewer and all reviewer-reviewer pairs. Second, we compared WC and EEG reviewers’ spike identification and individual spike class labels visually and quantitatively.

Results

The overlap between all WC-human pairs and all human pairs was >80% for 3/5 patients and >58% for the other 2 patients demonstrating WC falling within inter-human variation. The average sensitivity of spike marking for WC was 91% and >87% for all three EEG reviewers. Finally, there was a strong visual and quantitative similarity between WC and EEG reviewers.

Conclusions

WC performance is indistinguishable to that of EEG reviewers’ suggesting it could be a valid clinical tool for the assessment of IEDs.

Significance

WC can be used to provide quantitative analysis of epileptic spikes.
Keywords:Interictal spike classification  Intracranial EEG  Automated spike classification  Information theory