首页 | 本学科首页   官方微博 | 高级检索  
     


Comparison of three antigen detection tests for diagnosis and follow-up of falciparum malaria in travellers returning to Berlin,Germany
Authors:Martin P. Grobusch  Thomas Hänscheid  Klaus Göbels  Hortense Slevogt  Thomas Zoller  Gertrud Rögler  Dieter Teichmann
Affiliation:Department of Parasitology, Institute of Tropical Medicine, Eberhard Karls University, Wilhelmstrasse 27, 72074 Tuebingen, Germany. martin.grobusch@uni-tuebingen.de
Abstract:We determined the sensitivity and specificity of three rapid immunochromatographic malarial antigen detection test systems (RDTs) for the detection of Plasmodium falciparumand assessed the quality of follow-up results. ParaSight-F and ICT Malaria detect histidine-rich protein-2 (HRP-2), whereas OptiMal detects plasmodial lactate dehydrogenase (pLDH). ParaSight-F performed with 95.1% sensitivity and 97.1% specificity (554 patients tested of whom 144 had falciparum malaria). ICT Malaria performed with 95.7% sensitivity and 99.2% specificity (718 patients tested of whom 184 had falciparum malaria). OptiMal performed with 76.2% sensitivity and 99.7% specificity (539 patients tested of whom 130 had falciparum malaria). In follow-up investigations, HRP-2 did not appear to be a useful antigen due to its long half-life, whereas pLDH offers a reasonable correlation with the presence of viable parasites in those cases initially detected. We therefore conclude that a combination of both antigens might be the best option for creating a reliable RDT for the diagnosis of falciparum malaria.
Keywords:
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号