首页 | 本学科首页   官方微博 | 高级检索  
检索        

不同靶浓度舒芬太尼对异丙酚全麻患者脑电双频谱指数的影响
引用本文:杨宁,左明章.不同靶浓度舒芬太尼对异丙酚全麻患者脑电双频谱指数的影响[J].中华麻醉学杂志,2008,28(10).
作者姓名:杨宁  左明章
作者单位:100730,卫生部北京医院麻醉科
摘    要:目的 评价不同靶浓度舒芬太尼对异丙酚全麻患者脑电双频谱指数(BIS)的影响.方法 择期全麻手术患者50例,ASA Ⅰ或Ⅱ级,年龄18~57岁,随机分为5组(n=10),舒芬太尼效应室靶浓度(Ce)分别设定为0.07、0.10、0.14、0.20、0.28 ng/ml.持续监测BIS、平均动脉压(MAP)、心率(HR)、脉搏血氧饱和度、呼气末二氧化碳分压和心电图.麻醉诱导:异丙酚起始血浆靶浓度(Cp)3.0μg/ml,若Ce与Cp平衡后5 min意识仍未消失,以0.3 μg/ml浓度梯度递增,持续靶控输注(TCI)异丙酚,患者意识消失时记录异丙酚Cp和Ce,并维持该浓度,随后按预设不同Ce TCI舒芬太尼,每分钟记录BIS、HR,收缩压(SP)、舒张压(DP)和MAP.待舒芬太尼Ce与Cp平衡时,静脉注射琥珀酰胆碱1.5mg/kg,行气管插管.结果 各组意识消失时异丙酚Cp、Ce及BIS差异无统计学意义(P>0.05);TCI舒芬太尼后,BIS逐渐降低,当舒芬太尼Cp和Ce平衡时,BIS明显低于TCI舒芬太尼前水平(P<0.05);BIS与舒芬太尼Ce呈负相关(r=-0.419,P<0.05).结论 靶控输注舒芬太尼可进一步降低异丙酚全麻患者的BIS.

关 键 词:舒芬太尼  二异丙酚  药物释放系统  脑电描记术

Influence of different target concentrations of sufentanil TCI on BIS during propofol anesthesia
YANG Ning,ZUO Ming-zhang.Influence of different target concentrations of sufentanil TCI on BIS during propofol anesthesia[J].Chinese Journal of Anesthesilolgy,2008,28(10).
Authors:YANG Ning  ZUO Ming-zhang
Abstract:Objective To investigate the changes in BIS values induced by TCI of sufentanil at different target concentrations (Cr) during propofol anesthesia. Methods Fifty ASA Ⅰ or Ⅱ patients aged 18-57 yr undergoing elective surgery under general anesthesia were randomly divided into 5 groups (n = 10 each) based on CTof sufentanil: 0.07, 0.10, 0.14, 0.20 and 0.28 ng/ml. BIS, ECG, HR, MAP, SpO2, PET CO2 were continuously monitored. Anesthesia was induced with propofol TCI. The initial target plasma concentration (Cp) was set at 3.0 μg/ml. If the patient remained conscious 5 rain after the equilibrium between Cp and target effect-site concentration (Ce) was achieved, the Cp of propofol was increasing in increments of 0.3 μg/ml until consciousness was lost (LOC). Propofoi TCI was maintained at this level and Cp and Ce were recorded. TCI of safentanil was then started at the different Cp set in the 5 groups. When the equilibrium between Cp and Ce of safentanil was achieved, tracheal intubation was facilitated with succinyl choline 1.5 mg/kg and the patients were mechanically ventilated (VT= 8-10 mi/kg, RR = 8-12 bpm, PETCO2 = 30-35 mm Hg). BIS value, HR, MAP, SP and DP were recorded before induction of anesthesia at LOC (T0) and 1,2, 3, 4, 5 and 6 min after sufentanil TCI was started. Results There was no significant difference in Cp and Ce of propofol at LOC (T0) among the 5 groups. BIS value was decreasing after the beginning of TCI of sufentanil and was significantly lower than the BIS value at T0. The changes in BIS value was negatively correlated with the Cp and Ce of sufentanil. Conclusion TCI of sufentanil can decrease BIS value further during propofol anesthesia.
Keywords:Sufentanil  Propofol  Drug delivery systems  Electroencephalography
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号