首页 | 本学科首页   官方微博 | 高级检索  
     


Diagnostic Performance of PI-RADS v2, Proposed Adjusted PI-RADS v2 and Biparametric Magnetic Resonance Imaging for Prostate Cancer Detection: A Preliminary Study
Authors:Guan-Hui Cai  Qi-Hua Yang  Wen-Bo Chen  Qing-Yu Liu  Yu-Rong Zeng  Yu-Jing Zeng
Affiliation:1.Radiology Department, Huizhou Municipal Central Hospital, Huizhou 516001, China; (G.-H.C.); (W.-B.C.); (Y.-R.Z.); (Y.-J.Z.);2.Radiology Department, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou 510120, China;3.The Seventh Affiliated Hospital, Sun Yat-sen University, 628 Zhenyuan Road, Xinhu Street, Guangming New District, Shenzhen 518107, China
Abstract:Purpose: To evaluate the diagnostic performance of PI-RADS v2, proposed adjustments to PI-RADS v2 (PA PI-RADS v2) and biparametric magnetic resonance imaging (MRI) for prostate cancer detection. Methods: A retrospective cohort of 224 patients with suspected prostate cancer was included from January 2016 to November 2018. All the patients underwent a multi-parametric MR scan before biopsy. Two radiologists independently evaluated the MR examinations using PI-RADS v2, PA PI-RADS v2, and a biparametric MRI protocol, respectively. Receiver operating characteristic (ROC) curves for the three different protocols were drawn. Results: In total, 90 out of 224 cases (40.18%) were pathologically diagnosed as prostate cancer. The area under the ROC curves (AUC) for diagnosing prostate cancers by biparametric MRI, PI-RADS v2, and PA PI-RADS v2 were 0.938, 0.935, and 0.934, respectively. For cancers in the peripheral zone (PZ), the diagnostic sensitivity was 97.1% for PI-RADS v2/PA PI-RADS v2 and 96.2% for biparametric MRI. Moreover, the specificity was 84.0% for biparametric MRI and 58.0% for PI-RADS v2/PA PI-RADS v2. For cancers in the transition zone (TZ), the diagnostic sensitivity was 93.4% for PA PI-RADS v2 and 88.2% for biparametric MRI/PI-RADS v2. Furthermore, the specificity was 95.4% for biparametric MRI/PI-RADS v2 and 78.0% for PA PI-RADS v2. Conclusions: The overall diagnostic performance of the three protocols showed minimal differences. For lesions assessed as being category 3 using the biparametric MRI protocol, PI-RADS v2, or PA PI-RADS v2, it was thought prostate cancer detection could be improved. Attention should be paid to false positive results when PI-RADS v2 or PA PI-RADS v2 are used.
Keywords:prostate neoplasm   prostate cancer   multiparametric MRI   PI-RADS   Gleason score
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号