摘    要:目的:探讨在单支架横跨支架术式治疗左主干分叉病变中,使用血管内超声(IVUS)动态观察最终对吻技术对分叉区域解剖结构的影响。方法:前瞻性入组36例左主干分叉病变且行单支架横跨术式,所有患者在术前分别从前降支(run1)、回旋支(run2)回拉IVUS,支架释放后从前降支回拉IVUS(run3),最终对吻后分别从前降支(run4)、回旋支(run5)回拉IVUS;分析患者的临床特征、造影资料和IVUS数据。结果:患者年龄(63.8±12.1)岁,左主干真性分叉病变占22.2%。相较于术前IVUS(run2),最终对吻术后的IVUS(run5)发现回旋支开口处管腔面积[(7.30±3.08)mm2 vs(. 6.37±2.66)mm2,P<0.05]和血管面积[(13.10±3.27)mm2 vs.(12.47±2.93)mm2,P =0.012)]均明显减小,而斑块面积差异无统计学意义[(5.80±2.02)mm2 vs.( 6.10±2.09)mm2,P =0.128];回旋支开口处管腔面积变化与血管面积变化相关(r =0.787,P <0.001),而与斑块面积变化不相关(r =0.187,P =0.276)。相较于支架释放后IVUS(run3),最终对吻术后的IVUS(run4)发现多边形区域面积[(9.80±2.09)mm2 vs.( 11.48±2.65)mm2,P<0.05]、左主干远端面积[(9.91±1.73)mm2 vs.(11.85±2.38)mm2,P<0.05]和左主干最小支架内面积[(9.61±1.53)mm2 vs(. 11.34±2.33)mm2,P<0.05]均明显增加,支架贴壁不良现象减少(83.3% vs. 61.1%,P =0.035),但是伴随支架不对称指数增加,多边形区域[(1.23±0.14 vs. 1.33±0.12,P <0.05);左主干远端(1.18±0.09 vs. 1.25±0.10,P <0.05);左主干最小管腔面积处(1.17±0.09 vs. 1.24±0.10,P <0.05)。结论:在左主干分叉病变行单支架横跨支架术中,最终对吻后回旋支开口面积明显减小,与嵴移位相关;最终对吻增加左主干及多边形区域支架内面积,减少支架贴壁不良现象,但是会增加支架不对称指数。

关 键 词:单支架  左主干  冠脉介入  球囊对吻  血管内超声  
收稿时间:2021-04-19

The impact of final kissing balloon inflation on anatomical structure in single-stent technique strategy for left-main bifurcation lesion: a serial IVUS study
Lin Qingcheng,Zhu Qianli,Huang Weijian,Shan#br# Peiren. The impact of final kissing balloon inflation on anatomical structure in single-stent technique strategy for left-main bifurcation lesion: a serial IVUS study[J]. JOURNAL OF WENZHOU MEDICAL UNIVERSITY, 2021, 51(10): 793-799. DOI: 10.3969/j.issn.2095-9400.2021.10.004
Authors:Lin Qingcheng  Zhu Qianli  Huang Weijian  Shan#br# Peiren
Affiliation:Department of Cardiology, the First Affiliated Hospital of Wenzhou Medical University, Wenzhou325015, China
Abstract:Objective: To investigate the impact of final kissing balloon inflation (FKBI) on anatomical structure in single-stent crossover technique for left main artery bifurcation lesions with serial intravascular ultrasound (IVUS) imaging. Methods: Totally, 36 patients with left main artery bifurcation lesions were prospectively enrolled,and treated with single-stent crossover strategy. Serial IVUS pullback examinations were performed, including the runs of pre-intervention from both left anterior descending artery (LAD, run1) and left circumflex artery (LCX, run2), the run of post-stenting from LAD (run3), and the runs of post-FKBI from both LAD (run4) and LCX (run5). Results: The mean age of these patients was (63.8±12.1) years old, with left main true bifurcation lesion accounting for 22.2%. Compared with IVUS imaging of pre-intervention (run2), the ostium area of LCX was significantly decreased after FKBI [run5, (7.30±3.08)mm2 vs. (6.37±2.66)mm2, P<0.001], as well as vessel area [(13.10±3.27)mm2 vs. (12.47±2.93)mm2, P=0.012], however, there was no significant changes in plaque area [(5.80±2.02)mm2 vs. (6.10±2.09)mm2, P=0.128]. The change in lumen area within the LCX ostium was positivelycorrelated with the change in EEM area (r=0.787, P<0.05), but not with plaque area (r=0.187, P=0.276). Compared with IVUS imaging of post-stenting (run3), FKBI (run4) significantly increased the area at the site of polygon of confluence [POC, (9.80±2.09)mm2 vs. (11.48±2.65)mm2, P<0.05], distal left main [(9.91±1.73)mm2 vs. (11.85±2.38)mm2, P<0.05] and the minimal lumen area (MLA) of the left main [(9.61±1.53)mm2 vs. (11.34±2.33)mm2,P<0.05], decreased stent malapposition phenomena (83.3% vs. 61.1%, P=0.035), but increased the stent asymmetry index significantly (POC: 1.23±0.14 vs. 1.33±0.12, P<0.05; Distal LM: 1.18±0.09 vs. 1.25±0.10, P<0.05; MLA:1.17±0.09 vs. 1.24±0.10, P<0.05). Conclusion: Our analysis showed that carina shift, instead of plaque shift, was the main mechanism of LCX ostium compromise after FKBI in single-stent crossover technique for left-main bifurcation lesions. FKBI increased the stent area of the left main and POC, and decreased stent malapposition phenomena, at the cost of increasing stent symmetric index.