首页 | 本学科首页   官方微博 | 高级检索  
检索        

近视患者中央角膜厚度的相关因素研究
引用本文:李珊珊,向伟,杨学秋,赵静静,庄文娟,李自立.近视患者中央角膜厚度的相关因素研究[J].国际眼科杂志,2012,12(1):46-48.
作者姓名:李珊珊  向伟  杨学秋  赵静静  庄文娟  李自立
作者单位:1. 宁夏医科大学临床医学院,中国宁夏回族自治区银川市,750004
2. 宁夏医科大学总医院眼科,中国宁夏回族自治区银川市,750004
摘    要:目的:探讨影响近视患者中央角膜厚度(central corneal thickness,CCT)的因素。方法:本文所研究的近视及近视散光患者共307例614眼,用全自动电脑验光仪、角膜厚度测量仪、非接触式眼压计、A超、Orb-scan分别测量屈光状态、CCT,眼压(intraocular pressure,IOP)、眼轴(axial length,AL)、前房深度(anterior chamber depth,ACD)以及角膜曲率(corneal curvature,CC)。用Pearson相关分析及一元线性回归方法统计评估CCT与眼部参数的关系。结果:CCT平均值为542.30±33.52μm。Pearson相关分析显示CCT与IOP呈显著正相关(r=0.303,P=0.000),与平均CC呈显著负相关(r=-0.129,P=0.001),而与年龄(r=-0.050,P=0.213)、屈光度(r=0.024,P=0.561)、AL(r=0.061,P=0.131)、ACD(r=-0.031,P=0.445)等因素无关。结论:近视患者CCT与IOP及平均CC有相关性,CCT每增加100μm,IOP升高2.4mmHg。

关 键 词:近视  中央角膜厚度  相关因素
收稿时间:2011/9/20 0:00:00
修稿时间:2011/11/11 0:00:00

Study on factors related to central corneal thickness in patients with myopia
Shan-Shan Li,Wei Xiang,Xue-Qiu Yang,Jing-Jing Zhao,Wen-Juan Zhuang and Zi-Li Li.Study on factors related to central corneal thickness in patients with myopia[J].International Journal of Ophthalmology,2012,12(1):46-48.
Authors:Shan-Shan Li  Wei Xiang  Xue-Qiu Yang  Jing-Jing Zhao  Wen-Juan Zhuang and Zi-Li Li
Institution:Clinical College of Ningxia Medical University, Yinchuan 750004, Ningxia Hui Autonomous Region,China;;Department of Ophthalmology,General Hospital of Ningxia Medical University, Yinchuan 750004, Ningxia Hui Autonomous Region,China;Clinical College of Ningxia Medical University, Yinchuan 750004, Ningxia Hui Autonomous Region,China;;Clinical College of Ningxia Medical University, Yinchuan 750004, Ningxia Hui Autonomous Region,China;;Department of Ophthalmology,General Hospital of Ningxia Medical University, Yinchuan 750004, Ningxia Hui Autonomous Region,China;Department of Ophthalmology,General Hospital of Ningxia Medical University, Yinchuan 750004, Ningxia Hui Autonomous Region,China
Abstract:AIM:To determine the factors related to central corneal thickness(CCT) in patients with myopia.METHODS:A total of 307 patients(614 eyes) of myopia or myopia astigmatism subjects were examined.Refraction was measured by CANON RK-F1 automatic-refractor.CCT was measured by Pachymeter SP 3000.Axial Length was measured by A-mode ultrasound(OPTIKON 2000).Intraocular pressure(IOP) was measured by CANON TX-F non-contact tonometer.Corneal curvature was measured by Orbscan II(BAUSCH& LOMB).Age was also analyzed.The relationships between CCT and other parameters were tested by Pearson’s correlation and linear regression analysis.RESULTS:The average CCT was 542.30±33.52μm.CCT was positively correlated with IOP(r=0.303,P=0.000),negatively correlated with average corneal curvature(r=-0.129,P=0.001).There were no significant correlations between the CCT and age(r=-0.050,P=0.213),refractive error(r=0.024,P=0.561),axial length(r=0.061,P=0.131) and anterior chamber depth(r=-0.031,P=0.445).CONCLUSION:The CCT was correlated with IOP and average corneal curvature in patients of myopia.If the average CCT increases 100μm,the IOP would increase 2.4mmHg.
Keywords:myopia  central corneal thickness  relevantfactors
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《国际眼科杂志》浏览原始摘要信息
点击此处可从《国际眼科杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号