首页 | 本学科首页   官方微博 | 高级检索  
     

Pentacam分析仪比较正常和高度近视眼前房深度和前房角的研究
引用本文:代海燕,朴天华,林玉华,赵保文. Pentacam分析仪比较正常和高度近视眼前房深度和前房角的研究[J]. 国际眼科杂志, 2012, 12(3): 525-526. DOI: 10.3969/j.issn.1672-5123.2012.03.48
作者姓名:代海燕  朴天华  林玉华  赵保文
作者单位:牡丹江医学院红旗医院一门诊眼二科,中国黑龙江省牡丹江市,157100
基金项目:黑龙江省卫生厅科研课题资助
摘    要:目的:使用Pentacam三维眼前段分析仪比较高度近视眼与正常人(正视眼)中央前房深度(central anterior chamberdepth,CACD)和前房角(anterior chamber angle,ACA)两项前房参数差异,进一步了解高度近视眼的解剖学特点。方法:收集2010-10/2011-06在我院门诊就诊的正视眼82例,收集同期我院门诊与准分子激光中心就诊的高度近视眼68例,采用Pentacam三维眼前段分析仪测量CACD和ACA。对高度近视组与正视眼组的前房参数值进行两样本t检验,比较两组间参数有无差异。结果:Pentacam三维眼前段分析仪测得正常人CACD平均值为3.02±0.47mm,ACA平均值为33.26°±6.20°。高度近视眼的CACD平均值为3.24±0.38mm,ACA的平均值为39.55°±6.68°。高度近视眼与正视眼的两项前房参数值均存在显著性差异(均P〈0.05)。结论:Pentacam三维眼前段分析仪测量前房参数,高度近视眼与正视眼相比中央前房深度深、前房角宽。

关 键 词:中央前房深度  Pentacam三维眼前段分析仪  前房角
收稿时间:2011-11-28
修稿时间:2012-02-10

Comparison between emmetropia and high myopia eyes in central anterior chamber depth and anterior chamber angle with Pentacam
Hai-Yan Dai,Tian-Hua Piao,Yu-Hua Lin and Bao-Wen Zhao. Comparison between emmetropia and high myopia eyes in central anterior chamber depth and anterior chamber angle with Pentacam[J]. International Eye Science, 2012, 12(3): 525-526. DOI: 10.3969/j.issn.1672-5123.2012.03.48
Authors:Hai-Yan Dai  Tian-Hua Piao  Yu-Hua Lin  Bao-Wen Zhao
Affiliation:Department of Ophthalmology,the Affiliated Hospital of Mudanjiang Medical University,Mudanjiang 157100,Heilongjiang Province,China.;Department of Ophthalmology,the Affiliated Hospital of Mudanjiang Medical University,Mudanjiang 157100,Heilongjiang Province,China.;Department of Ophthalmology,the Affiliated Hospital of Mudanjiang Medical University,Mudanjiang 157100,Heilongjiang Province,China.;Department of Ophthalmology,the Affiliated Hospital of Mudanjiang Medical University,Mudanjiang 157100,Heilongjiang Province,China.
Abstract:AIM:To compare the differences in the central anterior chamber depth (CACD) and anterior chamber angle (ACA) measurements between emmetropia and high myopia eyes with Pentacam Scheimpflug. METHODS:In this prospective study, 82 healthy patients and 68 patients with myopia in the Affiliated Hospital of Mudanjiang Medical University were evaluated. Pentacam measurements were performed three times of one patient. A paired t-test was used to compare measurements of CACD and ACA width. The two groups were compared with SPSS 13.0. RESULTS:The differences in ACD and ACA values taken between the two groups were statistically significant (P<0.05). The ACD was deeper and the ACA was wider in patients with myopia. CONCLUSION:Patients with myopia have deeper ACD and wider ACA.
Keywords:central anterior chamber depth   Pentacam   anterior chamber angle
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《国际眼科杂志》浏览原始摘要信息
点击此处可从《国际眼科杂志》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号