股骨头骨骺早期缺血的动态Gadolinium增强MRI研究 |
| |
引用本文: | 彭雯佳,李小明,余铖,吴华,漆剑频,夏黎明,胡道予,胡军武,冯定义,邱丽,李宏莲. 股骨头骨骺早期缺血的动态Gadolinium增强MRI研究[J]. 中华骨科杂志, 2007, 29(1): 667-671. DOI: 10.3760/cma.j.issn.0253-2352.2009.07.013 |
| |
作者姓名: | 彭雯佳 李小明 余铖 吴华 漆剑频 夏黎明 胡道予 胡军武 冯定义 邱丽 李宏莲 |
| |
作者单位: | 4300030,武汉,华中科技大学同济医学院附属同济医院放射科;4300030,武汉,华中科技大学同济医学院附属同济医院骨科;4300030,武汉,华中科技大学同济医学院组织与胚胎学教研室; |
| |
摘 要: | 目的 比较动态Gadolinium(Gd)增强和常规Gd增强MR技术在早期缺血的股骨头骨骺中的灌注差异,并观察骨骺血管闭塞时生长板的血供.方法 28只2周龄乳猪,共56个髋关节,雄性12只,雌性16只;体重5~7 kg,平均6 kg;随机分为A、B、C、D组,每组7只.将A、B组乳猪的双髋关节极度外展固定30 min后,对A组行动态Gd增强FSPGR序列扫描,对B组行常规Gd增强SE T1WI序列扫描;行双髋关节外展体位的血管造影.之后让乳猪自由活动1 d,再采用双髋关节自然平放体位重复MR扫描.C、D组分别是A、B组的对照,即MR扫描前及扫描中双髋关节保持自然平放,C组行动态Gd增强扫描,D组行常规Gd增强扫描.最后将乳猪处死行组织学观察.结果 动态Gd增强MRI示:A组股骨头不同组织(除干骺端外)的强化率(ER)和强化速度(ES)均明显小于C组;A组生长板的ER和ES均小于干骺端,而C组生长板与干骺端的ER和ES值均无明显差异.常规Gd增强MRI示:B组股骨头各部分的ER与D组比较无明显下降.结论 对早期股骨头骨骺缺血的检测,动态Gd增强MRI技术比常规Gd增强SE T1WI技术更敏感.当骨骺血管闭塞时,生长板的血液灌注可能来自于干骺端.
|
关 键 词: | 磁共振成像 股骨头 骨骺 缺血 |
Dynamic Gadolinium-enhanced MRI in early ischaemia of the proximal femoral epiphysis |
| |
Abstract: | Objective To investigate the perfusion difference of early ischaemia of the proximal femoral epiphysis by MRI between with dynamic Gadolinium (Gd)-enhanced technique and conventional Gd-enhanced technique, respectively, and to observe the contribution of metaphyseal vascularity to physeal per-fusion in epiphyseal vascular occlusion. Methods Fifty-six hips of 28 two-week-old piglets were studied. All piglets were randomly divided into four groups (group A, B, C and D), with 7 in each. In group A and B, MR1 was performed bilaterally on the hips in persistent hyperabduction for 30 min. The piglets of group A underwent dynamic Gd-enhanced FSPGR MR scan, and those of group B did Gd-enhanced SE T1WI MR scan. The piglets of group C underwent dynamic Gd-enhaneed FSPGR MR scan, and those of group D did Gd-enhanced SE T1WI MR scan respectively without hyperabduction. Results On dynamic Gd-euhanced MRI, the enhancement ratio (ER) and enhancement speed (ES) of various region of interest (ROI) (except the metaphysis) in group A were significantly lower than those in group C. However, on conventional Gd-en-hanced SE T1WI, no significant decrease in the ER of each ROI in group B was found, compared with the ER in group D. In group A, the ER and ES of the physis were less than those of metaphysis on dynamic Gd-enhanced MRI; however, in group C, the ER and ES of the physis were similar to those of metaphysis. Con-clusion Dynamic Gd-enhanced MRI has an advantage in the detection of early epiphyseal ischaemia, com-pared with conventional Gd-enhanced SE T1WI. Metaphyseal vessels might play an important role in physeal perfusion with epiphyseal vascular occlusion. |
| |
Keywords: | Magnetic resonance imagingFemur headEpiphysesIschemia |
|
|