首页 | 本学科首页   官方微博 | 高级检索  
检索        

Preliminary clinical application using 3D time-resolved imaging of contrast-enhanced MR angiography of contrast kinetics (3D-TRICKS)i
引用本文:YANG Chun-shan 刘士远 肖湘生 冯云 李惠民 肖珊 龚万庆.Preliminary clinical application using 3D time-resolved imaging of contrast-enhanced MR angiography of contrast kinetics (3D-TRICKS)i[J].中国人民解放军军医大学学报,2007,22(1):43-48.
作者姓名:YANG  Chun-shan  刘士远  肖湘生  冯云  李惠民  肖珊  龚万庆
作者单位:[1]PET-CT center, PLA 455 Hospital, Shanghai 200052, China [2]Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai 200003, China
摘    要:Objective:To introduce a new better contrast-enhanced MR angiographic metnod, named 3D time-resolved imaging of contrast kinetics (3D-TRICKS). Methods: TRICKS is a high temporal resolution (2-6 s) MR angiographic technique using a short TR(4 ms) and TE(1.5 ms), partial echo sampling, in which central part of k-space is updated more frequently than the peripheral part. TRICKS pre-contrast mask 3D images are firstly scanned, and then the bolus injecting of Gd-DTPA, 15-20 sequential 3D images are acquired. The reconstructed 3D images, subtraction of contrast 3D images with mask images, are conceptually similar to a catheter-based intra-arterial digital subtraction angiographic series (DSA). Thirty patients underwent contrast-enhanced MR angiography using 3D-TRICKS. Results: Totally 12 vertebral arteries were well displayed on TRICKS, in which 7 were normal, 1 demonstrated bilateral vertebral artery stenosis, 4 had unilateral vertebral artery stenosis and 1 was accompanied with the same lateral carotid artery bifurcation stenosis. Four cases of bilateral renal arteries were normal, 1 transplanted kidney artery showed as normal and 1 transplanted kidney artery showed stenosis. 2 cerebral arteries were normal, 1 had sagittal sinus thrombosis and 1 displayed intracranial arteriovenous malformation. 3 pulmonary arteries were normal, 1 showed pulmonary artery thrombosis and 1 revealed pulmonary sequestration's abnormal feeding artery and draining vein. One left lower limb fibrolipoma showed feeding artery. One displayed radial-ulnar artery artificial fistula stenosis. One revealed left antebrachium hemangioma. Conclusion: TRICKS can clearly delineate most body vascular system and reveal most vascular abnormality. It possesses convenience and high successful rate, which make it the first choice of displaying most vascular abnormality.

关 键 词:对比增强磁共振血管造影术  三维动态血管造影  临床应用  血管畸形
收稿时间:2006-05-08
修稿时间:2006-12-07

Preliminary clinical application of contrast-enhanced MR angiography using 3D time-resolved imaging of contrast kinetics(3D-TRICKS)
YANG Chun-shan,LIU Shi-yuan,XIAO Xiang-sheng,FENG Yun,LI Hui-min,XIAO Shan,GONG Wan-qing.Preliminary clinical application of contrast-enhanced MR angiography using 3D time-resolved imaging of contrast kinetics(3D-TRICKS)[J].Journal of Medical Colleges of PLA(China),2007,22(1):43-48.
Authors:YANG Chun-shan  LIU Shi-yuan  XIAO Xiang-sheng  FENG Yun  LI Hui-min  XIAO Shan  GONG Wan-qing
Institution:YANG Chun-shan, LIU Shi-yuan, XIAO Xiang-sheng, FENG Yun, LI Hui-min, XIAO Shan, GONG Wan-qing( 1. PET-CT center, PLA 455 Hospital, Shanghai 200052, China ;2 Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai 200003, China)
Abstract:Objective To introduce a new better contrast-enhanced MR angiographic method, named 3D time-resolved imaging of contrast kinetics (3D-TRICKS). Methods TRICKS is a high temporal resolution (2-6 s) MR angiographic technique using a short TR(4 ms) and TE(1.5 ms), partial echo sampling, in which central part of k-space is updated more frequently than the peripheral part. TRICKS pre-contrast mask 3D images are firstly scanned, and then the bolus injecting of Gd-DTPA, 15-20 sequential 3D images are acquired. The reconstructed 3D images, subtraction of contrast 3D images with mask images, are conceptually similar to a catheter-based intra-arterial digital subtraction angiographic series(DSA). Thirty patients underwent contrast-enhanced MR angiography using 3D-TRICKS. Results Totally 12 vertebral arteries were well displayed on TRICKS, in which 7 were normal, 1 demonstrated bilateral vertebral artery stenosis, 4 had unilateral vertebral artery stenosis and 1 was accompanied with the same lateral carotid artery bifurcation stenosis. Four cases of bilateral renal arteries were normal, 1 transplanted kidney artery showed as normal and 1 transplanted kidney artery showed stenosis. 2 cerebral arteries were normal, 1 had sagittal sinus thrombosis and 1 displayed intracranial arteriovenous malformation. 3 pulmonary arteries were normal, 1 showed pulmonary artery thrombosis and 1 revealed pulmonary sequestration's abnormal feeding artery and draining vein. One left lower limb fibrolipoma showed feeding artery. One displayed radial-ulnar artery artificial fistula stenosis. One revealed left antebrachium hemangioma. Conclusion TRICKS can clearly delineate most body vascular system and reveal most vascular abnormality. It possesses convenience and high successful rate, which make it the first choice of displaying most vascular abnormality.
Keywords:magnetic resonance angiography  contrast-enhanced MR angiography  time-resolved imaging of contrast kinetics (TRICKS)  vascular malformation
本文献已被 维普 万方数据 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号