首页 | 本学科首页   官方微博 | 高级检索  
     


A fetal scalp electrode as a simple aid in the search for a lost needle fragment during sacrospinous ligament fixation
Authors:Marieke P. G. Schoonenberg  Kirsten B. Kluivers  Mark E. Vierhout
Affiliation:(1) Radboud University Nijmegen Medical Centre, Internal postal code 791, P.O. Box 9101, 6500, HB, Nijmegen, The Netherlands
Abstract:A needle fragment was lost during a sacrospinous ligament fixation. This was recognized during the procedure, but could not be found at that moment. The patient complained of severe buttock pain postoperatively. The needle fragment was localized on CT scan of the pelvis. A fetal scalp electrode helped as a search device to localize the needle on X-ray during the secondary surgery. The patient was operated successfully and was free of pain after 6 weeks.
Keywords:
本文献已被 SpringerLink 等数据库收录!